FHIR Release 3 (STU) R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.0.2: STU 3). (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R4 R3 R2

4.2.13.174 4.2.14.174 HL7 Version 2 Table 0174

Vocabulary Work Group   Maturity Level : N/A External Use Context : Any

This is a table defined as part of HL7 v2 . Related FHIR content: v2 Nature of Service/Test/Observation .

Summary

Name: v2 Nature of Service/Test/Observation
Definition:

FHIR Value set/code system definition for HL7 v2 table 0174 ( Nature of Service/Test/Observation)

Code System URL: http://hl7.org/fhir/v2/0174
Value Set URL: http://hl7.org/fhir/ValueSet/v2-0174
OID: ??
CodeSystem Resource XML / JSON
ValueSet Resource XML / JSON

This value set is used in the following places:

Nature of Service/Test/Observation This code system http://hl7.org/fhir/v2/0174 defines the following codes:

Code Description Deutsch (German) Display Nederlands (Dutch) Definition Comment Comments Version
A en: Atomic service/test/observation (test code or treatment code)
de: Einzeluntersuchung
nl: Atomische service/test/observatie (testcode of behandelingcode)
can encan be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments
nl: kan worden gekoppeld met een of meer OM4 (monster) segmenten. Een enkelvoudige, directe observatie en wordt meestal gekoppeld met een OM2 en/of OM3-segment
added v2.2
C en: Single observation calculated via a rule or formula from other independent observations (e.g. (e.g., Alveolar-arterial ratio, cardiac output)
de: Berechnetes Einzelergebnis
nl: Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)
can encan be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment
nl: kan worden gekoppeld met een of meer OM4 (monster) segmenten. Een afgeleide hoeveelheid en wordt meestal gekoppeld met een OM6 segment
added v2.2
F en: Functional procedure that may consist of one or more interrelated measures (e.g. (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens
de: Funktionstest
nl: Functionele behandeling die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantietest, creatinineklaring), meestal uitgevoerd op verschillende momenten en/of verschillende monsters
can encan be associated with one or more OM4 (specimen) segments<p>See comment for value S
nl: kan worden gekoppeld met een of meer OM4 (monster) segmenten. Zie opmerking voor waarde S
added v2.2
P en: Profile or battery consisting of many independent atomic observations (e.g. (e.g., SMA12, electrolytes), usually done at one instrument on one specimen
de: Batterieanordnung
nl: Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster
can encan be associated with one or more OM4 (specimen) segments<p>See comment for value S
nl: kan worden gekoppeld met een of meer OM4 (monster) segmenten. Zie opmerking voor waarde S
added v2.2
S en: Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g. (e.g., routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b
de: Latte von mehreren Batterieanforderungen (Aufnahmelatte)
nl: Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observaties
encan be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation
nl: kan worden gekoppeld met een of meer OM4 (monster) segmenten. Codes P, F, S identificeren sets (batteries) en moeten worden gekoppeld met een OM5-segment die de lijst van elementen definieert. De definities voor de elementen in de lijst moeten worden verzonden in andere onafhankelijke OMx-segmenten, een per element. In ASTM-context worden de meeste tekstuele rapporten - zoals ontslagsamenvattingen, opnameverslagen, thoraxrapporten - beschouwd als sets, waarin elke verslagsectie (bijv. omschrijving, indruk en advies van een radiologieverslag) als aparte observatie wordt gezien.
added v2.2

This code system http://hl7.org/fhir/v2/0174 defines the following codes:

Code Display Definition Comments Version
A Atomic service/test/observation (test code or treatment code) can be associated with one or more OM4 (specimen) segments<p>Codes segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments added v2.2
C Single observation calculated via a rule or formula from other independent observations (e.g., Alveolar-arterial ratio, cardiac output) can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment added v2.2
F Functional procedure that may consist of one or more interrelated measures (e.g., glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens can be associated with one or more OM4 (specimen) segments<p>See comment for value S added v2.2
P Profile or battery consisting of many independent atomic observations (e.g., SMA12, electrolytes), usually done at one instrument on one specimen can be associated with one or more OM4 (specimen) segments<p>See comment for value S added v2.2
S Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g., routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b can be associated with one or more OM4 (specimen) segments Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements. The definitions for the contained elements would have to be sent in o other independent OMx segments, one for each contained element. In the ASTM context, most text reports – such as discharge summaries, admission H&Ps, and chest X-ray reports – are considered as sets, in which each section of the report (e.g., description, impression, and recommendation of an X-ray report) is considered a separate observation added v2.2

This code system http://hl7.org/fhir/v2/0174 defines the following codes:

Code Display Definition Comments Version
A Einzeluntersuchung added v2.2
C Berechnetes Einzelergebnis added v2.2
F Funktionstest added v2.2
P Batterieanordnung added v2.2
S Latte von mehreren Batterieanforderungen (Aufnahmelatte) added v2.2

Dit code systeem http://hl7.org/fhir/v2/0174 definieert de volgende codes:

Code Display Definition Commentaar Versie
A Atomische service/test/observatie (testcode of behandelingcode) kan worden gekoppeld met een of meer OM4 (monster) segmenten. Een enkelvoudige, directe observatie en wordt meestal gekoppeld met een OM2 en/of OM3-segment added v2.2
C Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume) kan worden gekoppeld met een of meer OM4 (monster) segmenten. Een afgeleide hoeveelheid en wordt meestal gekoppeld met een OM6 segment added v2.2
F Functionele behandeling die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantietest, creatinineklaring), meestal uitgevoerd op verschillende momenten en/of verschillende monsters kan worden gekoppeld met een of meer OM4 (monster) segmenten. Zie opmerking voor waarde S added v2.2
P Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster kan worden gekoppeld met een of meer OM4 (monster) segmenten. Zie opmerking voor waarde S added v2.2
S Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observaties kan worden gekoppeld met een of meer OM4 (monster) segmenten. Codes P, F, S identificeren sets (batteries) en moeten worden gekoppeld met een OM5-segment die de lijst van elementen definieert. De definities voor de elementen in de lijst moeten worden verzonden in andere onafhankelijke OMx-segmenten, een per element. In ASTM-context worden de meeste tekstuele rapporten - zoals ontslagsamenvattingen, opnameverslagen, thoraxrapporten - beschouwd als sets, waarin elke verslagsectie (bijv. omschrijving, indruk en advies van een radiologieverslag) als aparte observatie wordt gezien. added v2.2