DSTU2 FHIR Release 3 (STU)

This page is part of the FHIR Specification (v1.0.2: DSTU (v3.0.2: STU 2). 3). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2 R3 R2

Valueset-allergy-intolerance-criticality.xml

Vocabulary Work Group Maturity Level : N/A Ballot Status : Informative

Raw XML ( canonical form )

Definition for Value SetAllergyIntoleranceCriticality


  
  
    
    
  
  
    
    
      
      Estimate of the potential clinical harm, or seriousness, of a reaction to an identified
         Substance.
      This value set has an inline code system http://hl7.org/fhir/allergy-intolerance-criticality,
         which defines the following codes:
      
        
          
            
          
          
            
          
          
            
          
        
        
          CRITL
            
          
          
          The potential clinical impact of a future reaction is estimated as low risk: exposure
             to substance is unlikely to result in a life threatening or organ system threatening outcome.
             Future exposure to the Substance is considered a relative contra-indication.
        
        
          CRITH
            
          
          
          The potential clinical impact of a future reaction is estimated as high risk: exposure
             to substance may result in a life threatening or organ system threatening outcome. Future
             exposure to the Substance may be considered an absolute contra-indication.
        
        
          CRITU
            
          
          
          
        
      
    
  
  
    
  
  
  
  
  
  
  
  
    
      
      
    
    
      
      
    
  
  
  Estimate of the potential clinical harm, or seriousness, of a reaction to an identified
   Substance.
  
    
      
    
    
    
    
    
      
      
      The potential clinical impact of a future reaction is estimated as low risk: exposure
       to substance is unlikely to result in a life threatening or organ system threatening outcome.
       Future exposure to the Substance is considered a relative contra-indication.
    
    
      
      
      The potential clinical impact of a future reaction is estimated as high risk: exposure
       to substance may result in a life threatening or organ system threatening outcome. Future
       exposure to the Substance may be considered an absolute contra-indication.
    
    
      
      
      
    
  

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="allergy-intolerance-criticality"/> 
  <meta> 
    <lastUpdated value="2019-10-24T11:53:00+11:00"/> 
    <profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/> 
  </meta> 
  <text> 
    <status value="generated"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">
      <h2> AllergyIntoleranceCriticality</h2> 
      <div> 
        <p> Estimate of the potential clinical harm, or seriousness, of a reaction to an identified
           substance.</p> 

      </div> 
      <p> This value set includes codes from the following code systems:</p> 
      <ul> 
        <li> Include all codes defined in 
          <a href="codesystem-allergy-intolerance-criticality.html">
            <code> http://hl7.org/fhir/allergy-intolerance-criticality</code> 
          </a> 
        </li> 
      </ul> 
    </div> 
  </text> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status">
    <valueString value="Informative"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="3"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="pc"/> 
  </extension> 
  <url value="http://hl7.org/fhir/ValueSet/allergy-intolerance-criticality"/> 
  <identifier> 
    <system value="urn:ietf:rfc:3986"/> 
    <value value="urn:oid:2.16.840.1.113883.4.642.3.119"/> 
  </identifier> 
  <version value="3.0.2"/> 
  <name value="AllergyIntoleranceCriticality"/> 
  <status value="draft"/> 
  <experimental value="false"/> 
  <date value="2019-10-24T11:53:00+11:00"/> 
  <publisher value="HL7 (FHIR Project)"/> 
  <contact> 
    <telecom> 
      <system value="url"/> 
      <value value="http://hl7.org/fhir"/> 
    </telecom> 
    <telecom> 
      <system value="email"/> 
      <value value="fhir@lists.hl7.org"/> 
    </telecom> 
  </contact> 
  <description value="Estimate of the potential clinical harm, or seriousness, of a reaction to an identified

   substance."/> 
  <immutable value="true"/> 
  <compose> 
    <include> 
      <system value="http://hl7.org/fhir/allergy-intolerance-criticality"/> 
    </include> 
  </compose> 


</

ValueSet

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.