This
page
is
part
of
the
FHIR
Specification
(v1.0.2:
DSTU
(v3.0.2:
STU
2).
3).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
R2
R3
R2
| Health Care Devices Work Group | Maturity Level : N/A | Ballot Status : Informative | Compartments : Device |
General DeviceMetric example
{
"resourceType": "DeviceMetric",
"id": "example",
"text": {
"status": "generated",
"div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>type</b>: MDC_PULS_OXIM_SAT_O2 <span>(Details : {https://rtmms.nist.gov code '150456' = '??', given as 'MDC_PULS_OXIM_SAT_O2'})</span></p><p><b>identifier</b>: 345675</p><p><b>unit</b>: MDC_DIM_PERCENT <span>(Details : {https://rtmms.nist.gov code '262688' = '??', given as 'MDC_DIM_PERCENT'})</span></p><p><b>category</b>: measurement</p></div>"
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>identifier</b>: 345675</p><p><b>type</b>: MDC_PULS_OXIM_SAT_O2 <span>(Details : {https://rtmms.nist.gov code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})</span></p><p><b>unit</b>: MDC_DIM_PERCENT <span>(Details : {https://rtmms.nist.gov code '262688' = '262688', given as 'MDC_DIM_PERCENT'})</span></p><p><b>source</b>: <a>Device/dev1</a></p><p><b>parent</b>: <a>DeviceComponent/dc102</a></p><p><b>operationalStatus</b>: on</p><p><b>color</b>: blue</p><p><b>category</b>: measurement</p><p><b>measurementPeriod</b>: Do Once per 1 seconds</p><h3>Calibrations</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>State</b></td><td><b>Time</b></td></tr><tr><td>*</td><td>two-point</td><td>calibrated</td><td>28/12/2016 9:03:04 AM</td></tr></table></div>"
},
"identifier": {
"system": "http://goodcare.org/devicemetric/id",
"value": "345675"
},
"type": {
"coding": [
{
"system": "https://rtmms.nist.gov",
"code": "150456",
"display": "MDC_PULS_OXIM_SAT_O2"
}
]
},
"identifier": {
"system": "http://goodcare.org/devicemetric/id",
"value": "345675"
},
"unit": {
"coding": [
{
"system": "https://rtmms.nist.gov",
"code": "262688",
"display": "MDC_DIM_PERCENT"
}
]
},
"category": "measurement"
"source": {
"reference": "Device/dev1"
},
"parent": {
"reference": "DeviceComponent/dc102"
},
"operationalStatus": "on",
"color": "blue",
"category": "measurement",
"measurementPeriod": {
"repeat": {
"frequency": 1,
"period": 1,
"periodUnit": "s"
}
},
"calibration": [
{
"type": "two-point",
"state": "calibrated",
"time": "2016-12-28T09:03:04-05:00"
}
]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.