DSTU2 FHIR Release 3 (STU)

This page is part of the FHIR Specification (v1.0.2: DSTU (v3.0.2: STU 2). 3). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R3 R2 R3 R2

Devicecomponent-example.xml

Health Care Devices Work Group Maturity Level : N/A Ballot Status : Informative Compartments : Device

Raw XML ( canonical form )

Jump past Narrative

General DeviceComponent example (id = "example")


  <!--   
    <Simple_MDS xmlns:xsd="http://www.w3.org/2001/XMLSchema-instance" xsd:noNamespaceSchemaLocation="D
  IM.xsd" Handle="0" System-Id="ID 13.1" Mds-Status="disconnected" object_id="MDC_MOC_VMS_MDS_SIMP"
   Class="MDC_MOC_VMS_MDS_SIMP">
      <Nomenclature-Version object_id="MDC_ATTR_NOM_VERS" nom-minor-version="0">
        <nom-major-version majorVersion1="true"/>
      </Nomenclature-Version>
      <System-Model object_id="MDC_ATTR_ID_MODEL" manufacturer="Center4MI" model-number="2-0-14"/>
      <System-Type object_id="MDC_ATTR_SYS_TYPE" partition="nom-part-obj" code="MDC_DEV_ANALY_SAT_O2_MD
  S"/>
      <Locale object_id="MDC_ATTR_LOCALE" charset="ISO-10646-UCS-2" country="US" Language="en"/>
      <VMD Handle="20" object_id="MDC_MOC_VMO_VMD" Class="MDC_MOC_VMO_VMD">
        <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-obj" code="MDC_DEV_ANALY_SAT_O2_VMD"/>
        <VMD-Status vmd-standby="true"/>
        <Channel Handle="22" object_id="MDC_MOC_VMO_CHAN" Class="MDC_MOC_VMO_CHAN" Physical-Channel-No="
  1" Logical-Channel-No="1" Channel-Id="MDC_DEV_ANALY_SAT_O2_CHAN">
          <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-obj" code="MDC_DEV_ANALY_SAT_O2_CHAN"/>
          <Channel-Status chan-standby="true"/> 
          <Numeric Handle="221" object_id="MDC_MOC_VMO_METRIC_NU" Class="MDC_MOC_VMO_METRIC_NU"
   Nu-Measure-Resolution="0" Metric-Id="MDC_PULS_OXIM_SAT_O2">
            <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-metric" code="MDC_PULS_OXIM_SAT_O2"/>
            <Metric-Specification object_id="MDC_ATTR_METRIC_SPECN" update-period="8192" category="auto-me
  asurement">
              <relevance rv-unspec="true"/> 
              <access upd-periodic="true" acc-scan="true" sc-opt-normal="true"/>
              <structure object_id="NA1" ms-comp-no="0" ms-struct="simple"/>
            </Metric-Specification>
            <Nu-Observed-Value object_id="MDC_ATTR_NU_VAL_OBS" value="0" unit-code="MDC_DIM_PERCENT"
   metric-id="MDC_PULS_OXIM_SAT_O2">
              <state not-available="true"/>
            </Nu-Observed-Value>
          </Numeric>
          <Numeric Handle="222" object_id="MDC_MOC_VMO_METRIC_NU" Class="MDC_MOC_VMO_METRIC_NU"
   Nu-Measure-Resolution="0" Metric-Id="MDC_BLD_PERF_INDEX">
            <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-metric" code="MDC_BLD_PERF_INDEX"/>
            <Metric-Specification object_id="MDC_ATTR_METRIC_SPECN" update-period="8192" category="auto-me
  asurement">
              <relevance rv-unspec="true"/> 
              <access upd-periodic="true" acc-scan="true" sc-opt-normal="true"/>
              <structure object_id="NA1" ms-comp-no="0" ms-struct="simple"/>
            </Metric-Specification>
            <Nu-Observed-Value object_id="MDC_ATTR_NU_VAL_OBS" value="0" unit-code="MDC_DIM_MILLI_L_PER_MI
  N" metric-id="MDC_BLD_PERF_INDEX">
              <state not-available="true"/>
            </Nu-Observed-Value>
          </Numeric>
        </Channel>
        <Channel Handle="33" object_id="MDC_MOC_VMO_CHAN" Class="MDC_MOC_VMO_CHAN" Physical-Channel-No="
  2" Logical-Channel-No="2" Channel-Id="MDC_DEV_PULS_CHAN">
          <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-obj" code="MDC_DEV_PULS_CHAN"/>
          <Channel-Status chan-standby="true"/> 
          <Numeric Handle="333" object_id="MDC_MOC_VMO_METRIC_NU"  Class="MDC_MOC_VMO_METRIC_NU"
   Nu-Measure-Resolution="0" Metric-Id="MDC_PULS_OXIM_PULS_RATE">
            <Type object_id="MDC_ATTR_ID_TYPE" partition="nom-part-metric" code="MDC_PULS_OXIM_PULS_RATE"/
  >
            <Metric-Specification object_id="MDC_ATTR_METRIC_SPECN" update-period="8192" category="auto-me
  asurement">
              <relevance rv-unspec="true"/> 
              <access upd-periodic="true" acc-scan="true" sc-opt-normal="true"/>
              <structure object_id="NA1" ms-comp-no="0" ms-struct="simple"/>
            </Metric-Specification>
            <Nu-Observed-Value object_id="MDC_ATTR_NU_VAL_OBS" value="0" unit-code="MDC_DIM_BEAT_PER_MIN"
   metric-id="MDC_PULS_OXIM_PULS_RATE">
              <state not-available="true"/>
            </Nu-Observed-Value>
          </Numeric>
        </Channel>
      </VMD>
    </Simple_MDS>
    -->
   
  
    
    
      
    
  

  
    
      
      
        
          
            
            
          
        
        
      
      
        
          
        
        
        
      
      
        
           
          
          
        
      
      
            
    
  
  
  
    
       
      
      
    
  
  
    
    
  
  
  
    
    
  
    
       
      
      
    
  
  
    
      
      
    
  

<DeviceComponent xmlns="http://hl7.org/fhir">
  <id value="example"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example</p> <p> <b> identifier</b> : 0</p> <p> <b> type</b> : MDC_DEV_ANALY_SAT_O2_MDS <span> (Details : {urn:iso:std:iso:11073:10101 code '2000' = '2000', given as 'MDC_DEV_ANALY_SAT_O2_MDS'})</span> </p> <p> <b> lastSystemChange</b> : 07/10/2014 2:45:00 PM</p> <p> <b> source</b> : <a> Device/d1</a> </p> <p> <b> parent</b> : <a> DeviceComponent/dc1</a> </p> <p> <b> operationalStatus</b> : Off <span> (Details : {urn:iso:std:iso:11073:10101 code 'off' = 'off', given as 'Off'})</span> </p> <p> <b> parameterGroup</b> : Miscellaneous Parameter Group <span> (Details : {urn:iso:std:iso:11073:10101 code 'miscellaneous' = 'miscellaneous', given
           as 'Miscellaneous Parameter Group'})</span> </p> <p> <b> measurementPrinciple</b> : optical</p> <p> <b> languageCode</b> : en-US <span> (Details : {http://tools.ietf.org/html/bcp47 code 'en-US' = 'en-US)</span> </p> </div> </text> <identifier> 
    <value value="0"/> 
  </identifier> 
  <type> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="2000"/> 
      <display value="MDC_DEV_ANALY_SAT_O2_MDS"/> 
    </coding> 
  </type> 
  <lastSystemChange value="2014-10-07T14:45:00Z"/> 
  <source> 
    <reference value="Device/d1"/> 
  </source> 
  <parent> 
    <reference value="DeviceComponent/dc1"/> 
  </parent> 
  <operationalStatus> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="off"/> 
      <display value="Off"/> 
    </coding> 
  </operationalStatus> 
  <parameterGroup> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="miscellaneous"/> 
      <display value="Miscellaneous Parameter Group"/> 
    </coding> 
  </parameterGroup> 
  <measurementPrinciple value="optical"/> 
  <languageCode> 
    <coding> 
      <system value="http://tools.ietf.org/html/bcp47"/> 
      <code value="en-US"/> 
    </coding> 
  </languageCode> 


</

DeviceComponent

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.