Release 4B 5

This page is part of the FHIR Specification (v4.3.0: R4B (v5.0.0: R5 - STU ). The This is the current published version which supercedes in it's permanent home (it will always be available at this version is 5.0.0 . URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R5 R4B R4

Specimendefinition-example-serum-plasma

Example SpecimenDefinition/2364 (Narrative)

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Not linked to any No defined compartments

This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .


Generated Narrative Narrative: SpecimenDefinition

Resource SpecimenDefinition "2364"

url : http://example.com/specdef/v1/12345

identifier : id: 12345

title : Example Specimen Definition for Testing

status : active

experimental : false

typeCollected : Venous blood specimen ( SNOMED CT #122555007)

patientPreparation : 12 hour fasting () , At rest ( SNOMED CT #263678003)

timeAspect : preferrably morning time

typeTested

isDerived : false

type : Serum specimen ( SNOMED CT #119364003)

preference : preferred

Containers

- Material Type Cap MinimumVolume[x]
* plastic ( SNOMED CT #61088005) Evacuated blood collection tube, thrombin/clot activator/gel separator ( SNOMED CT #702281005) yellow cap (unknown#yellow) 2 ml (Details: UCUM code mL = 'mL')

handling

temperatureQualifier : Ambient temperature ()

temperatureRange : 15-25 °C

MaxDurations

- Value Unit System Code
* 60 minute Unified Code for Units of Measure (UCUM) min

handling

temperatureQualifier : Refrigerated temperature ()

temperatureRange : 2-8 °C

MaxDurations

- Value Unit System Code
* 8 hour Unified Code for Units of Measure (UCUM) h

typeTested

type : Plasma specimen ( SNOMED CT #119361006)

preference : alternate

Containers

- Material Type Cap MinimumVolume[x]
* glass ( SNOMED CT #32039001) Evacuated blood collection tube with heparin lithium and gel tube, thrombin/clot activator/gel separator ( SNOMED CT #767390000) #702281005) green cap (unknown#green) 2 ml (Details: UCUM code mL = 'mL')

rejectionCriterion : insufficient specimen volume ( RejectionCriterion #insufficient) , hemolized specimen ( RejectionCriterion #hemolized)

handling

temperatureQualifier : Ambient temperature ()

temperatureRange : 15-25 °C

MaxDurations

- Value Unit System Code
* 60 minute Unified Code for Units of Measure (UCUM) min

handling

temperatureQualifier : Refrigerated temperature ()

temperatureRange : 2-8 °C

MaxDurations

- Value Unit System Code
* 8 hour Unified Code for Units of Measure (UCUM) h

 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.