Clinical
Reasoning
This
page
is
part
of
the
FHIR
Specification
(v4.3.0:
R4B
(v5.0.0:
R5
-
STU
).
The
This
is
the
current
published
version
which
supercedes
in
it's
permanent
home
(it
will
always
be
available
at
this
version
is
5.0.0
.
URL).
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R5
R4B
R4
R3
| Clinical Decision Support Work Group | Maturity Level : N/A | Standards Status : Informative |
Compartments
:
|
Raw JSON ( canonical form + also see JSON Format Specification )
Example of guidanceresponse
{
"resourceType": "GuidanceResponse",
"id": "example",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource "example" </p></div><p><b>requestIdentifier</b>: id: guidanceRequest1</p><p><b>identifier</b>: id: guidanceResponse1</p><p><b>module</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</p><p><b>encounter</b>: <a href=\"encounter-example.html\">Encounter/example</a></p><p><b>occurrenceDateTime</b>: 2017-03-10T16:02:00Z</p><p><b>performer</b>: <a href=\"todo.html\">Device/software</a></p><p><b>reasonCode</b>: Guideline Appropriate Ordering Assessment <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>outputParameters</b>: <a name=\"outputParameters1\"> </a></p><blockquote><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource "outputParameters1" </p></div><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: CT, head, wo iv contrast <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-CPT.html\">Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a href=\"todo.html\">Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>"
"resourceType" : "GuidanceResponse",
"id" : "example",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: GuidanceResponse</b><a name=\"example\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource GuidanceResponse "example" </p></div><p><b>requestIdentifier</b>: id:\u00a0guidanceRequest1</p><p><b>identifier</b>: id:\u00a0guidanceResponse1</p><p><b>module</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</p><p><b>encounter</b>: <a href=\"encounter-example.html\">Encounter/example</a></p><p><b>occurrenceDateTime</b>: 2017-03-10T16:02:00Z</p><p><b>performer</b>: <a href=\"broken-link.html\">Device/software</a></p><h3>Reasons</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Guideline Appropriate Ordering Assessment <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table><p><b>outputParameters</b>: <a name=\"outputParameters1\"> </a></p><blockquote><p/><p><a name=\"outputParameters1\"> </a></p><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: CT, head, wo iv contrast <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-CPT.html\">Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a href=\"broken-link.html\">Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a href=\"http://someguidelineprovider.org/radiology-appropriateness-guidelines.html\">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>"
},
"contained": [
"contained" : [{
"resourceType" : "Parameters",
"id" : "outputParameters1",
"parameter" : [{
"name" : "score",
"valueDecimal" : 7
},
{
"resourceType": "Parameters",
"id": "outputParameters1",
"parameter": [
{
"name": "score",
"valueDecimal": 7
},
{
"name": "item-assessed",
"valueCodeableConcept": {
"coding": [
{
"system": "http://www.ama-assn.org/go/cpt",
"code": "70450",
"display": "CT, head, wo iv contrast"
}
]
}
},
{
"name": "device",
"valueReference": {
"reference": "Device/software"
}
},
{
"name": "guideline-followed",
"valueUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"
}
]
}
],
"requestIdentifier": {
"system": "http://example.org",
"value": "guidanceRequest1"
},
"identifier": [
"name" : "item-assessed",
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://www.ama-assn.org/go/cpt",
"code" : "70450",
"display" : "CT, head, wo iv contrast"
}]
}
},
{
"system": "http://example.org",
"value": "guidanceResponse1"
}
],
"moduleUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html",
"status": "success",
"subject": {
"reference": "Patient/example"
"name" : "device",
"valueReference" : {
"reference" : "Device/software"
}
},
{
"name" : "guideline-followed",
"valueUri" : "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"
}]
}],
"requestIdentifier" : {
"system" : "http://example.org",
"value" : "guidanceRequest1"
},
"encounter": {
"reference": "Encounter/example"
"identifier" : [{
"system" : "http://example.org",
"value" : "guidanceResponse1"
}],
"moduleUri" : "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html",
"status" : "success",
"subject" : {
"reference" : "Patient/example"
},
"occurrenceDateTime": "2017-03-10T16:02:00Z",
"performer": {
"reference": "Device/software"
"encounter" : {
"reference" : "Encounter/example"
},
"reasonCode": [
{
"text": "Guideline Appropriate Ordering Assessment"
"occurrenceDateTime" : "2017-03-10T16:02:00Z",
"performer" : {
"reference" : "Device/software"
},
"reason" : [{
"concept" : {
"text" : "Guideline Appropriate Ordering Assessment"
}
],
"outputParameters": {
"reference": "#outputParameters1"
}],
"outputParameters" : {
"reference" : "#outputParameters1"
}
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
Release
4B
(v4.3.0)
hl7.fhir.r4b.core#4.3.0
R5
hl7.fhir.core#5.0.0
generated
on
Sat,
May
28,
2022
12:55+1000.
Sun,
Mar
26,
2023
15:24+1100.
Links:
Search
|
Version
History
|
Table
of
Contents
|
Glossary
|
QA
Page
|
Compare
to
R4
|
Compare
to
R4B
|
|
Propose
a
change