This
page
is
part
of
the
FHIR
Specification
(v4.0.1:
R4
(v5.0.0:
R5
-
Mixed
Normative
and
STU
)
).
This
is
the
current
published
version
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
R2
Devicemetric-example.xml
Example
DeviceMetric/example
(XML)
Raw
XML
(
canonical
form
+
also
see
XML
Format
Specification
)
Jump
past
Narrative
General
DeviceMetric
example
(id
=
"example")
<?xml version="1.0" encoding="UTF-8"?>
<DeviceMetric xmlns="http://hl7.org/fhir">
<id value="example"/>
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: DeviceMetric</b> <a name="example"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource DeviceMetric "example" </p> </div> <p> <b> identifier</b> : id: 345675</p> <p> <b> type</b> : MDC_PULS_OXIM_SAT_O2 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #150456)</span> </p> <p> <b> unit</b> : MDC_DIM_PERCENT <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #262688)</span> </p> <p> <b> device</b> : <a href="broken-link.html">Device/dev1</a> </p> <p> <b> operationalStatus</b> : on</p> <p> <b> color</b> : blue</p> <p> <b> category</b> : measurement</p> <p> <b> measurementFrequency</b> : 1 Hertz<span style="background: LightGoldenRodYellow"> (Details: UCUM code Hz = 'Hz')</span> </p> <h3> Calibrations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> State</b> </td> <td> <b> Time</b> </td> </tr> <tr> <td> *</td> <td> two-point</td> <td> calibrated</td> <td> 29 Dec 2016, 1:03:04 am</td> </tr> </table> </div> </text> <identifier>
<system value="http://goodcare.org/devicemetric/id"/> <value value="345675"/> </identifier> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="150456"/> <display value="MDC_PULS_OXIM_SAT_O2"/> </coding> </type> <unit> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="262688"/> <display value="MDC_DIM_PERCENT"/> </coding> </unit> <device> <reference value="Device/dev1"/> </device> <operationalStatus value="on"/> <color value="blue"/> <category value="measurement"/> <measurementFrequency> <value value="1"/> <unit value="Hertz"/> <system value="http://unitsofmeasure.org"/> <code value="Hz"/> </measurementFrequency> <calibration> <type value="two-point"/> <state value="calibrated"/> <time value="2016-12-28T09:03:04-05:00"/> </calibration>
</
DeviceMetric
>
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.