Release 4 5

This page is part of the FHIR Specification (v4.0.1: R4 (v5.0.0: R5 - Mixed Normative and STU ) ). This is the current published version in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Devicemetric-example.xml

Example DeviceMetric/example (XML)

Health Care Devices Work Group Maturity Level : N/A Standards Status : Informative Compartments : Not linked to any No defined compartments

Raw XML ( canonical form + also see XML Format Specification )

Jump past Narrative

General DeviceMetric example (id = "example")

<?xml version="1.0" encoding="UTF-8"?>


  
  
    
    
  
  
    
      
      
      
    
  
  
    
      
      
      
    
  
  
    
  
  
    
  
  
  
  
  
    
      
      
      
    
  
  
    
    
    
  

<DeviceMetric xmlns="http://hl7.org/fhir">
  <id value="example"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: DeviceMetric</b> <a name="example"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource DeviceMetric &quot;example&quot; </p> </div> <p> <b> identifier</b> : id: 345675</p> <p> <b> type</b> : MDC_PULS_OXIM_SAT_O2 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #150456)</span> </p> <p> <b> unit</b> : MDC_DIM_PERCENT <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #262688)</span> </p> <p> <b> device</b> : <a href="broken-link.html">Device/dev1</a> </p> <p> <b> operationalStatus</b> : on</p> <p> <b> color</b> : blue</p> <p> <b> category</b> : measurement</p> <p> <b> measurementFrequency</b> : 1 Hertz<span style="background: LightGoldenRodYellow"> (Details: UCUM code Hz = 'Hz')</span> </p> <h3> Calibrations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> State</b> </td> <td> <b> Time</b> </td> </tr> <tr> <td> *</td> <td> two-point</td> <td> calibrated</td> <td> 29 Dec 2016, 1:03:04 am</td> </tr> </table> </div> </text> <identifier> 
    <system value="http://goodcare.org/devicemetric/id"/>     <value value="345675"/>   </identifier>   <type>     <coding>       <system value="urn:iso:std:iso:11073:10101"/>       <code value="150456"/>       <display value="MDC_PULS_OXIM_SAT_O2"/>     </coding>   </type>   <unit>     <coding>       <system value="urn:iso:std:iso:11073:10101"/>       <code value="262688"/>       <display value="MDC_DIM_PERCENT"/>     </coding>   </unit>   <device>     <reference value="Device/dev1"/>   </device>   <operationalStatus value="on"/>   <color value="blue"/>   <category value="measurement"/>    <measurementFrequency>     <value value="1"/>      <unit value="Hertz"/>      <system value="http://unitsofmeasure.org"/>      <code value="Hz"/>    </measurementFrequency>   <calibration>     <type value="two-point"/>     <state value="calibrated"/>     <time value="2016-12-28T09:03:04-05:00"/>   </calibration> 


</

DeviceMetric

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.