Terminology
This
page
is
part
of
the
FHIR
Specification
(v4.3.0:
R4B
(v5.0.0:
R5
-
STU
).
The
This
is
the
current
published
version
which
supercedes
in
it's
permanent
home
(it
will
always
be
available
at
this
version
is
5.0.0
.
URL).
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R5
R4B
R4
R3
| FHIR Infrastructure Work Group | Maturity Level : N/A | Standards Status : Informative |
Raw XML ( canonical form + also see XML Format Specification )
Definition for Code SystemBindingStrength
<?xml version="1.0" encoding="UTF-8"?>required extensible To be conformant, the concept in this element SHALL be from the specified value set if any of the codes within the value set can apply to the concept being communicated. If the value set does not cover the concept (based on human review), alternate codings (or, data type allowing, text) may be included instead. preferred Instances are encouraged to draw from the specified codes for interoperability purposes but are not required to do so to be considered conformant. example Instances are not expected or even encouraged to draw from the specified value set. The value set merely provides examples of the types of concepts intended to be included. To be conformant, the concept in this element SHALL be from the specified value set if any of the codes within the value set can apply to the concept being communicated. If the value set does not cover the concept (based on human review), alternate codings (or, data type allowing, text) may be included instead. Instances are encouraged to draw from the specified codes for interoperability purposes but are not required to do so to be considered conformant. Instances are not expected or even encouraged to draw from the specified value set. The value set merely provides examples of the types of concepts intended to be included.<CodeSystem xmlns="http://hl7.org/fhir"> <id value="binding-strength"/> <meta> <lastUpdated value="2023-03-26T15:21:02.749+11:00"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p> This code system <code> http://hl7.org/fhir/binding-strength</code> defines the following codes: </p> <table class="codes"> <tr> <td style="white-space:nowrap"> <b> Code</b> </td> <td> <b> Display</b> </td> <td> <b> Definition</b> </td> </tr> <tr> <td style="white-space:nowrap">required <a name="binding-strength-required"> </a> </td> <td> Required</td> <td> To be conformant, the concept in this element SHALL be from the specified value set.</td> </tr> <tr> <td style="white-space:nowrap">extensible <a name="binding-strength-extensible"> </a> </td> <td> Extensible</td> <td> To be conformant, the concept in this element SHALL be from the specified value set if any of the codes within the value set can apply to the concept being communicated. If the value set does not cover the concept (based on human review), alternate codings (or, data type allowing, text) may be included instead.</td> </tr> <tr> <td style="white-space:nowrap">preferred <a name="binding-strength-preferred"> </a> </td> <td> Preferred</td> <td> Instances are encouraged to draw from the specified codes for interoperability purposes but are not required to do so to be considered conformant.</td> </tr> <tr> <td style="white-space:nowrap">example <a name="binding-strength-example"> </a> </td> <td> Example</td> <td> Instances are not expected or even encouraged to draw from the specified value set. The value set merely provides examples of the types of concepts intended to be included.</td> </tr> </table> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="fhir"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"> <valueCode value="normative"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-normative-version"> <valueCode value="4.0.0"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="5"/> </extension> <url value="http://hl7.org/fhir/binding-strength"/> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.840.1.113883.4.642.4.44"/> </identifier> <version value="5.0.0"/> <name value="BindingStrength"/> <title value="BindingStrength"/> <status value="active"/> <experimental value="false"/> <date value="2023-03-26T15:21:02+11:00"/> <description value="Indication of the degree of conformance expectations associated with a binding."/> <jurisdiction> <coding> <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/> <code value="001"/> <display value="World"/> </coding> </jurisdiction> <caseSensitive value="true"/> <valueSet value="http://hl7.org/fhir/ValueSet/binding-strength"/> <content value="complete"/> <concept> <code value="required"/> <display value="Required"/> <definition value="To be conformant, the concept in this element SHALL be from the specified value set."/> </concept> <concept> <code value="extensible"/> <display value="Extensible"/> <definition value="To be conformant, the concept in this element SHALL be from the specified value set if any of the codes within the value set can apply to the concept being communicated. If the value set does not cover the concept (based on human review), alternate codings (or, data type allowing, text) may be included instead."/> </concept> <concept> <code value="preferred"/> <display value="Preferred"/> <definition value="Instances are encouraged to draw from the specified codes for interoperability purposes but are not required to do so to be considered conformant."/> </concept> <concept> <code value="example"/> <display value="Example"/> <definition value="Instances are not expected or even encouraged to draw from the specified value set. The value set merely provides examples of the types of concepts intended to be included."/> </concept> </ CodeSystem >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
Release
4B
(v4.3.0)
hl7.fhir.r4b.core#4.3.0
R5
hl7.fhir.core#5.0.0
generated
on
Sat,
May
28,
2022
12:49+1000.
Sun,
Mar
26,
2023
15:22+1100.
Links:
Search
|
Version
History
|
Table
of
Contents
|
Glossary
|
QA
Page
|
Compare
to
R4
|
Compare
to
R4B
|
|
Propose
a
change