Release 4 4B

This page is part of the FHIR Specification (v4.0.1: R4 (v4.3.0: R4B - Mixed Normative and STU ) in it's permanent home (it will always be available at this URL). ). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R4B R4

Specimendefinition-example-serum-plasma

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Not linked to any defined compartments

This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .


Generated Narrative with Details

id : 2364

Resource "2364"

typeCollected : Venous blood specimen (Details : {SNOMED ( SNOMED CT code '122555007' = 'Venous blood specimen', given as 'Venous blood specimen'}) #122555007)

patientPreparation : 12 hour fasting (Details ) () , At rest (Details : {SNOMED ( SNOMED CT code '263678003' = 'At rest', given as 'At rest'}) #263678003)

timeAspect : preferrably morning time

typeTested

type : Serum specimen (Details : {SNOMED ( SNOMED CT code '119364003' = 'Serum specimen', given as 'Serum specimen'}) #119364003)

preference : preferred

Containers

- Material Type Cap MinimumVolume[x]
* plastic (Details : {SNOMED ( SNOMED CT code '61088005' = 'Plastic', given as 'plastic'}) #61088005) Evacuated blood collection tube, thrombin/clot activator/gel separator (Details : {SNOMED ( SNOMED CT code '702281005' = 'Evacuated blood collection tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube, thrombin/clot activator/gel separator'}) #702281005) yellow cap (Details : {urn:iso:std:iso:6710:2017 code 'yellow' = 'yellow', given as 'yellow cap'}) (unknown#yellow) 2 ml (Details: UCUM code mL = 'mL')

handling

temperatureQualifier : Ambient temperature (Details ) ()

temperatureRange : 15-25 °C

maxDuration : 60 minute (Details: UCUM code min = 'min')

handling

temperatureQualifier : Refrigerated temperature (Details ) ()

temperatureRange : 2-8 °C

maxDuration : 8 hour (Details: UCUM code h = 'h')

typeTested

type : Plasma specimen (Details : {SNOMED ( SNOMED CT code '119361006' = 'Plasma specimen', given as 'Plasma specimen'}) #119361006)

preference : alternate

Containers

- Material Type Cap MinimumVolume[x]
* glass (Details : {SNOMED ( SNOMED CT code '32039001' = 'Glass', given as 'glass'}) #32039001) Evacuated blood collection tube with heparin lithium and gel separator (Details : {SNOMED ( SNOMED CT code '767390000' = 'Evacuated blood collection tube with heparin lithium and gel separator', given as 'Evacuated blood collection tube with heparin lithium and gel separator'}) #767390000) green cap (Details : {urn:iso:std:iso:6710:2017 code 'green' = 'green', given as 'green cap'}) (unknown#green) 2 ml (Details: UCUM code mL = 'mL')

rejectionCriterion : insufficient specimen volume (Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'insufficient' = 'insufficient specimen volume', given as 'insufficient specimen volume'}) ( RejectionCriterion #insufficient) , hemolized specimen (Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'hemolized' = 'hemolized specimen', given as 'hemolized specimen'}) ( RejectionCriterion #hemolized)

handling

temperatureQualifier : Ambient temperature (Details ) ()

temperatureRange : 15-25 °C

maxDuration : 60 minute (Details: UCUM code min = 'min')

handling

temperatureQualifier : Refrigerated temperature (Details ) ()

temperatureRange : 2-8 °C

maxDuration : 8 hour (Details: UCUM code h = 'h')

 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.