FHIR Release 3 (STU) 4

This page is part of the FHIR Specification (v3.0.2: (v4.0.1: R4 - Mixed Normative and STU 3). ) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R4 R3 R4 R3 R2

4.2.13.914 4.3.15.914 HL7 Version 2 Table 0914

Vocabulary Work Group   Maturity Level : N/A External Use Context : Any

This is a table defined as part of HL7 v2 . Related FHIR content: v2 Root Cause .

Summary

http://hl7.org/fhir/v2/0914 http://hl7.org/fhir/ValueSet/v2-0914
Name: Code System URL: v2 Root Cause http://terminology.hl7.org/CodeSystem/v2-0914
Definition: Value Set URL: FHIR Value set/code system definition for HL7 v2 table 0914 ( Root Cause) http://terminology.hl7.org/ValueSet/v2-0914
Code System URL: Version: 2.9
Name: v2.0914
Value Set URL: Title: v2 Root Cause
Definition:

FHIR Value set/code system definition for HL7 v2 table 0914 ( Root Cause)

OID: ??
CodeSystem Resource XML / JSON
ValueSet Resource XML / JSON

This value set is used in Note: V2 code systems may or may not be case sensitive. V2 Code systems will have the following places: CodeSystem.caseSensitive correctly populated in a future version of this specification.

This value set is the designated 'entire code system' value set for v2 Root Cause not currently used

Root Cause

Code Description Comment Version
AP Analysis Process Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure added v2.8
IM Information Management Enter (IM) when INFORMATION MANAGEMENT is the reason due to:<p>• to: • Database or Programming issues<p>• issues • Overriding of test results<p>• results • Inaccurate calculations<p>• calculations • Inaccurate flagging, reference ranges, units of measure<p>• measure • Incomplete/inaccurate tran transmission of test results • Other added v2.8
L Laboratory Enter (L) when LABORATORY is the reason due to:<p>• to: • Data Entry error<p>• error • Testing/Technical error<p>• error • Repeat testing causing change to test result added v2.8
NA Not Applicable Enter (NA) when NOT-APPLICABLE is the reason due to:<p>• to: • If no revisions performed or<p>• or • unable to determine reason for revision<p>Note: revision Note: Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a cor correction (revision) added v2.8
PD Placer Data Enter (PD) when new or changed PLACER DATA information is the reason due to:<p>• to: • Changed patient demographics or<p>• or • Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous Biopsy Date, Clinical Information, Source, etc...) added v2.8