This
page
is
part
of
the
FHIR
Specification
(v3.0.2:
(v4.0.1:
R4
-
Mixed
Normative
and
STU
3).
)
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
R4
R3
| Orders and Observations Work Group | Maturity Level : N/A |
|
Compartments : Device , Patient , Practitioner , RelatedPerson |
Raw XML ( canonical form + also see XML Format Specification )
Simple order for resupply (id = "simpleorder")
<?xml version="1.0" encoding="UTF-8"?> <SupplyRequest xmlns="http://hl7.org/fhir"> <id value="simpleorder"/>(Details : {[not stated] code 'BlueTubes' = 'BlueTubes', given as 'Blood collect tubes blue cap'})<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : simpleorder</p> <p> <b> identifier</b> : Order10284</p> <p> <b> status</b> : active</p> <p> <b> category</b> : Central Stock Resupply <span> (Details : {[not stated] code 'central' = 'central', given as 'Central Stock Resupply'})</span> </p> <p> <b> priority</b> : asap</p> <p> <b> item</b> : Blood collect tubes blue cap <span> (Details : {[not stated] code 'BlueTubes' = 'BlueTubes', given as 'Blood collect tubes blue cap'})</span> </p> <p> <b> quantity</b> : 10</p> <p> <b> occurrence</b> : 31/12/2016</p> <p> <b> authoredOn</b> : 31/12/2016</p> <p> <b> requester</b> : Henry Seven</p> <p> <b> supplier</b> : Vendor1</p> <p> <b> reasonCode</b> : Refill due to low stock <span> (Details : {[not stated] code 'stock_low' = 'stock_low', given as 'Refill due to low stock'})</span> </p> <p> <b> deliverFrom</b> : Location 1</p> <p> <b> deliverTo</b> : GoodHealth Clinic Receiving</p> </div> </text> <identifier> <value value="Order10284"/> </identifier> <status value="active"/> <category> <coding> <code value="central"/> <display value="Central Stock Resupply"/> </coding> </category> <priority value="asap"/><itemCodeableConcept> <coding> <code value="BlueTubes"/> <display value="Blood collect tubes blue cap"/> </coding> </itemCodeableConcept> <quantity> <value value="10"/> </quantity> <occurrenceDateTime value="2016-12-31"/> <authoredOn value="2016-12-31"/> <requester><display value="Henry Seven"/> </requester> <supplier> <display value="Vendor1"/> </supplier><reasonCode> <coding> <code value="stock_low"/> <display value="Refill due to low stock"/> </coding> </reasonCode> <deliverFrom> <display value="Location 1"/> </deliverFrom> <deliverTo> <display value="GoodHealth Clinic Receiving"/> </deliverTo> </ SupplyRequest >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.