FHIR Release 3 (STU) 4

This page is part of the FHIR Specification (v3.0.2: (v4.0.1: R4 - Mixed Normative and STU 3). ) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R4 R3 R2

Provenance-example-sig.xml

Security Work Group Maturity Level : N/A Ballot Standards Status : Informative Compartments : Device , Patient , Practitioner , RelatedPerson

Raw XML ( canonical form + also see XML Format Specification )

Jump past Narrative

Provenance holding a signature (id = "signature")

<?xml version="1.0" encoding="UTF-8"?>


<Provenance xmlns="http://hl7.org/fhir">
  <id value="signature"/> 
  <text> 
    <status value="generated"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">procedure record authored on 27-June 2015 by Harold Hippocrates, MD Content extracted
       from Referral received 26-June</div> 
  </text> 
  <!--   
    where possible, provenance targets should be version specific,
    so that there is no ambiguity about which version of the 
    record this relates to
    -->
  <target> 
    <reference value="DocumentReference/example"/>     
  </target> 
  <recorded value="2015-08-27T08:39:24+10:00"/> 
  <reason> 
    
    
    

    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-ActReason"/> 
      <code value="TREAT"/> 
      <display value="treatment"/> 
    </coding> 
  </reason> 
  <activity> 
      
      
      

    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-DocumentCompletion"/> 
      <code value="AU"/> 
      <display value="authenticated"/> 
    </coding> 
  </activity> 
 



  <!--   signer = Harold Hippocrates   -->
  <agent> 
    
      
        

    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/contractsignertypecodes"/> 
        <code value="VERF"/> 
      
    

      </coding> 
    </type> 

    <!--   very often, the user won't have a known system - these aren't available 
      for security system log ons. But where you can define it, you should.
      Most of the time the userId is fully qualfied such as an email address      -->
    

    <who> 
      <identifier> 
        <system value="urn:ietf:rfc:3986"/> 
        <value value="mailto://hhd@ssa.gov"/> 
      </identifier> 
    </who> 
  </agent> 
   
  

  <signature> 
    <!--   verification signature   -->
    <type> 
    
    
    
  
  
    
      
      
  
  

      <system value="urn:iso-astm:E1762-95:2013"/> 
      <code value="1.2.840.10065.1.12.1.5"/> 
      <display value="Verification Signature"/> 
    </type> 
    <when value="2015-08-27T08:39:24+10:00"/> 
    <who> 
      <reference value="Practitioner/xcda-author"/> 
    </who>   
    <targetFormat value="application/fhir+xml"/> 
    <sigFormat value="application/signature+xml"/> 
    <data value="Li4u"/> 
  </signature> 


</

Provenance

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.