FHIR Release 3 (STU) 4

This page is part of the FHIR Specification (v3.0.2: (v4.0.1: R4 - Mixed Normative and STU 3). ) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R4 R3

4.2.12.417 4.3.14.433 Code System http://hl7.org/fhir/device-action

Vocabulary Patient Care Work Group   Maturity Level : 3 0 Informative Use Context : Not Intended for Production use Any

This is a code system defined at http://www.hl7.org/Special/committees/patientcare/ .

Summary

Defining URL: http://hl7.org/fhir/device-action
Version: 4.0.1
Name: ProcedureDeviceActionCodes
Title: Procedure Device Action Codes
Definition:

Example codes indicating the change that happened to the device during the procedure. Note that these are in no way complete and may might not even be appropriate for some uses.

Committee: Patient Care Work Group
OID: 2.16.840.1.113883.4.642.1.417 2.16.840.1.113883.4.642.4.426 (for OID based terminology systems)
Copyright:

This value set resource includes content from SNOMED CT, Clinical Terms® (SNOMED CT®) which is copyright © 2002+ of the International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT is not covered by this agreement. Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org

Source Resource XML / JSON

This Code system is not currently used

Example codes indicating the change that happened to the device during the procedure. Note that these are in no way complete and may might not even be appropriate for some uses.

Copyright Statement:

This value set resource includes content from SNOMED CT, Clinical Terms® (SNOMED CT®) which is copyright © 2002+ of the International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT is not covered by this agreement. Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org

This code system http://hl7.org/fhir/device-action defines the following codes:

Code Display Definition
implanted Implanted The device was implanted in the patient during the procedure.
explanted Explanted The device was explanted from the patient during the procedure.
manipulated Manipulated The device remains in that the patient, but its location, settings, or functionality was changed.

 

See the full registry of value sets code systems defined as part of FHIR.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies See Code System for further information.
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding ). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept