DSTU2

This page is part of the FHIR Specification (v0.0.82: (v1.0.2: DSTU 1). 2). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

5.12.7 5.12.6 Resource DeviceMetric - Examples

Example Index: List:

5.12.7.1 General XML General DeviceMetric example (id = "example") </DeviceMetric> JSON General DeviceMetric example Raw JSON ( Canonical ) { "resourceType": "DeviceMetric", "id": "example", "text": { "status": "generated", "div": "<div>!-- Snipped for Brevity --></div>" }, "type": { "coding": [ { "system": "https://rtmms.nist.gov", "code": "150456", "display": "MDC_PULS_OXIM_SAT_O2" } ] }, "identifier": { "system": "http://goodcare.org/devicemetric/id", "value": "345675" }, "unit": { "coding": [ { "system": "https://rtmms.nist.gov", "code": "262688", "display": "MDC_DIM_PERCENT" } ] }, "category": "measurement" }
General DeviceMetric example XML JSON Raw XML
 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.