Release 4 R6 Ballot (1st Full Ballot)

This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU v6.0.0-ballot4: Release 6 Ballot (1st Full Ballot) (see Ballot Notes ) in it's permanent home (it will always be available at this URL). ). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 for published versions

Observation-example-vitals-panel.xml

Example Observation/vitals-panel (XML)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw XML ( canonical form + also see XML Format Specification )

Jump past Narrative

Simple Panel of Heart Rate, Repiratory Rate. Blood Pressure and Body Temperature (id = "vitals-panel")

<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="vitals-panel"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/> 
  </meta> 
  (Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'vital-signs'
           = 'Vital Signs', given as 'Vital Signs'})(Details : {LOINC code '85353-1' = 'Vital signs, weight, height, head circumference, oxygen
           saturation &amp; BMI panel', given as 'Vital signs, weight, height, head circumference,
           oxygen saturation and BMI panel'})

  <status value="final"/> 
  <category> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/observation-category"/> 
      <code value="vital-signs"/> 
      <display value="Vital Signs"/> 
    </coding> 
    <text value="Vital Signs"/> 
  </category> 
  <!--    Deprecated LOINC -replaced  by 85353-1 for this profile

  <code> 
    <!--   Deprecated LOINC -replaced  by 85353-1 for this profile
    <coding>
      <system value="http://loinc.org"/>
      <code value="8716-3"/>
      <display value="Vital signs"/>
    </coding>
   -->

  -->
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="85353-1"/> 
      <display value="Vital signs, weight, height, head circumference, oxygen saturation and BMI panel"/> 
    </coding> 
    <text value="Vital signs Panel"/> 
  </code> 
  <subject> 
    

    <reference value="Patient/example"/> 
  </subject> 
  <effectiveDateTime value="1999-07-02"/> 
  <hasMember> 
    
    

    <reference value="Observation/respiratory-rate"/> 
    <display value="Respiratory Rate"/> 
  </hasMember> 
  <hasMember> 
    
    

    <reference value="Observation/heart-rate"/> 
    <display value="Heart Rate"/> 
  </hasMember> 
  <hasMember> 
    
    

    <reference value="Observation/blood-pressure"/> 
    <display value="Blood Pressure"/> 
  </hasMember> 
  <hasMember> 
    
    

    <reference value="Observation/body-temperature"/> 
    <display value="Body Temperature"/> 
  </hasMember> 


</

Observation

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.