| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : No defined compartments |
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .
Generated Narrative: SpecimenDefinition 2364
url : http://example.com/specdef/v1/12345
identifier
:
id: 12345
12345
title : Example Specimen Definition for Testing
status : active
experimental : false
publisher : HL7 International / Orders and Observations
contact : http://www.hl7.org/Special/committees/orders
typeCollected
:
Venous
blood
specimen
(
SNOMED
CT
#122555007)
patientPreparation
:
12
hour
fasting
()
,
At
rest
(
SNOMED
CT
#263678003)
timeAspect : preferrably morning time
typeTested
isDerived : false
type : Serum specimen
( SNOMED CT #119364003)preference : preferred
Containers
Material Type Cap MinimumVolume[x] plastic ( SNOMED CT #61088005)Evacuated blood collection tube, thrombin/clot activator/gel separator ( SNOMED CT #702281005)yellow cap (unknown#yellow)2 ml (Details: UCUM code mLcodemL = 'mL')handling
temperatureQualifier : Ambient temperature
()temperatureRange : 15-25 °C
MaxDurations
Value Unit System Code 60 minute Unified Code for Units of Measure (UCUM)http://unitsofmeasure.orgmin handling
temperatureQualifier : Refrigerated temperature
()temperatureRange : 2-8 °C
MaxDurations
Value Unit System Code 8 hour Unified Code for Units of Measure (UCUM)http://unitsofmeasure.orgh
typeTested
type : Plasma specimen
( SNOMED CT #119361006)preference : alternate
Containers
Material Type Cap MinimumVolume[x] glass ( SNOMED CT #32039001)Evacuated blood collection tube, thrombin/clot activator/gel separator ( SNOMED CT #702281005)green cap (unknown#green)2 ml (Details: UCUM code mLcodemL = 'mL')rejectionCriterion : insufficient specimen volume
( RejectionCriterion #insufficient), hemolized specimen( RejectionCriterion #hemolized)handling
temperatureQualifier : Ambient temperature
()temperatureRange : 15-25 °C
MaxDurations
Value Unit System Code 60 minute Unified Code for Units of Measure (UCUM)http://unitsofmeasure.orgmin handling
temperatureQualifier : Refrigerated temperature
()temperatureRange : 2-8 °C
MaxDurations
Value Unit System Code 8 hour Unified Code for Units of Measure (UCUM)http://unitsofmeasure.orgh
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.