Conformance
This
page
is
part
of
the
FHIR
Specification
(v5.0.0:
R5
-
STU
v6.0.0-ballot2:
Release
6
Ballot
(2nd
Draft)
(see
Ballot
Notes
).
This
is
the
The
current
published
version
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
| Clinical Quality Information Work Group | Maturity Level : N/A | Standards Status : Informative |
Raw JSON ( canonical form + also see JSON Format Specification )
Operation Definition
{
"resourceType" : "OperationDefinition",
"id" : "Measure-submit-data",
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>URL: [base]/Measure/$submit-data</p><p>URL: [base]/Measure/[id]/$submit-data</p><p>Parameters</p><table class=\"grid\"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Scope</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>measureReport</td><td/><td>1..1</td><td><a href=\"measurereport.html\">MeasureReport</a></td><td/><td><div><p>The measure report being submitted</p>\n</div></td></tr><tr><td>IN</td><td>resource</td><td/><td>0..*</td><td><a href=\"resource.html\">Resource</a></td><td/><td><div><p>The individual resources that make up the data-of-interest being submitted</p>\n</div></td></tr></table><div><p>The effect of invoking this operation is that the submitted data is posted to the receiving system and can be used for subsequent calculation of the relevant quality measure. The data-of-interest for a measure can be determined by examining the measure definition, or by invoking the $data-requirements operation</p>\n</div></div>"
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: OperationDefinition Measure-submit-data</b></p><a name=\"Measure-submit-data\"> </a><a name=\"hcMeasure-submit-data\"> </a><a name=\"Measure-submit-data-en-AU\"> </a><p>URL: [base]/Measure/$submit-data</p><p>URL: [base]/Measure/[id]/$submit-data</p><p>Parameters</p><table class=\"grid\"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Scope</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>measureReport</td><td/><td>1..1</td><td><a href=\"measurereport.html\">MeasureReport</a></td><td/><td><div><p>The measure report being submitted</p>\n</div></td></tr><tr><td>IN</td><td>resource</td><td/><td>0..*</td><td><a href=\"resource.html\">Resource</a></td><td/><td><div><p>The individual resources that make up the data-of-interest being submitted</p>\n</div></td></tr></table><div><p>The effect of invoking this operation is that the submitted data is posted to the receiving system and can be used for subsequent calculation of the relevant quality measure. The data-of-interest for a measure can be determined by examining the measure definition, or by invoking the $data-requirements operation</p>\n</div></div>"
},
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger" : 3
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode" : "trial-use"
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "cqi"
}],
"url" : "http://hl7.org/fhir/OperationDefinition/Measure-submit-data",
"version" : "5.0.0",
"version" : "6.0.0-ballot2",
"name" : "SubmitData",
"title" : "Submit Data",
"status" : "draft",
"kind" : "operation",
"experimental" : false,
"date" : "2023-03-26T15:21:02+11:00",
"publisher" : "HL7 (FHIR Project)",
"date" : "2024-08-12T16:52:12+08:00",
"publisher" : "HL7 International / Clinical Quality Information",
"contact" : [{
"telecom" : [{
"system" : "url",
"value" : "http://hl7.org/fhir"
},
{
"system" : "email",
"value" : "fhir@lists.hl7.org"
}]
},
{
"telecom" : [{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/cqi"
}]
}],
"description" : "The submit-data operation is used to submit data-of-interest for a measure. There is no expectation that the submitted data represents all the data-of-interest, only that all the data submitted is relevant to the calculation of the measure for a particular subject or population",
"jurisdiction" : [{
"coding" : [{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001",
"display" : "World"
}]
}],
"affectsState" : false,
"code" : "submit-data",
"comment" : "The effect of invoking this operation is that the submitted data is posted to the receiving system and can be used for subsequent calculation of the relevant quality measure. The data-of-interest for a measure can be determined by examining the measure definition, or by invoking the $data-requirements operation",
"resource" : ["Measure"],
"system" : false,
"type" : true,
"instance" : true,
"parameter" : [{
"name" : "measureReport",
"use" : "in",
"min" : 1,
"max" : "1",
"documentation" : "The measure report being submitted",
"type" : "MeasureReport"
},
{
"name" : "resource",
"use" : "in",
"min" : 0,
"max" : "*",
"documentation" : "The individual resources that make up the data-of-interest being submitted",
"type" : "Resource"
}]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
R5
hl7.fhir.core#5.0.0
R6
hl7.fhir.core#6.0.0-ballot2
generated
on
Sun,
Mar
26,
2023
15:25+1100.
Mon,
Aug
12,
2024
16:58+0800.
Links:
Search
|
Version
History
|
Contents
|
Glossary
|
QA
|
Compare
to
R4
|
Compare
to
R4B
R5
|
|
Propose
a
change