Release 5 R6 Ballot (2nd Draft)

This page is part of the FHIR Specification (v5.0.0: R5 - STU v6.0.0-ballot2: Release 6 Ballot (2nd Draft) (see Ballot Notes ). This is the The current published version in it's permanent home (it will always be available at this URL). is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Example Observation/satO2 (XML)

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Device , Encounter , Patient , Practitioner , RelatedPerson

Raw XML ( canonical form + also see XML Format Specification )

Jump past Narrative

Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile) (id = "satO2")

<?xml version="1.0" encoding="UTF-8"?>

<!--  
 This example is taken from the v3 data types (SLIST)
   --><Observation xmlns="http://hl7.org/fhir">

  <id value="satO2"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/> 
  </meta> 
  display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%

  <identifier> 
    <system value="http://goodcare.org/observation/id"/> 
    <value value="o1223435-10"/> 
  </identifier> 
  <partOf> 
    <reference value="Procedure/ob"/> 
  </partOf> 
  <status value="final"/> 
  <category> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/observation-category"/> 
      <code value="vital-signs"/> 
      <display value="Vital Signs"/> 
    </coding> 
    <text value="Vital Signs"/> 
  </category> 
  
    

  <category> 
    <coding> 
      <system value="http://loinc.org"/> 
          

      <!--   LOINC   -->
      <code value="2708-6"/> 
      <display value="Oxygen saturation in Arterial blood"/> 
    
        <!--    Example of a translation to a more specific code  to the vitals profile LOINC
     code    -->

    </coding> 
  </category> 
  <code> 
    <!--   Example of a measurement code that is more specific than the vitals profile LOINC
     code   -->

    <coding> 
      <system value="http://loinc.org"/> 
          

      <!--   LOINC   -->
      <code value="59408-5"/> 
      <display value="Oxygen saturation in Arterial blood by Pulse oximetry"/> 
    </coding> 
        <!--    Example of a translation to a more specific code  to the vitals profile LOINC
     code    -->

    <!--   Record of original machine code   -->
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
          

      <!--      mdc      -->
      <code value="150456"/> 
      <display value="MDC_PULS_OXIM_SAT_O2"/> 
    </coding> 
  </code> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <effectiveDateTime value="2014-12-05T09:30:10+01:00"/> 
  <valueQuantity> 
    <value value="95"/> 
    <unit value="%"/> 
    <system value="http://unitsofmeasure.org"/> 
    <code value="%"/> 
  </valueQuantity> 
  <interpretation> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> 
      <code value="N"/> 
      <display value="Normal"/> 
    </coding> 
    <text value="Normal (applies to non-numeric results)"/> 
  </interpretation> 
  <device> 
    <reference value="DeviceMetric/example"/> 
  </device> 
  <referenceRange> 
    <low> 
      <value value="90"/> 
      <unit value="%"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="%"/> 
    </low> 
    <high> 
      <value value="99"/> 
      <unit value="%"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="%"/> 
    </high> 
  </referenceRange> 


</

Observation

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.