| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : No defined compartments |
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .
Generated Narrative: SpecimenDefinition
Resource SpecimenDefinition "2364"
StructureDefinition Work Group : oo
url
:
http://example.com/specdef/v1/12345
identifier : id: 12345
title : Example Specimen Definition for Testing
status : active
experimental : false
publisher : HL7 International / Orders and Observations
contact :
typeCollected : Venous blood specimen ( SNOMED CT #122555007)
patientPreparation : 12 hour fasting () , At rest ( SNOMED CT #263678003)
timeAspect : preferrably morning time
typeTested
isDerived : false
type : Serum specimen ( SNOMED CT #119364003)
preference : preferred
Containers
Material Type Cap MinimumVolume[x] plastic ( SNOMED CT #61088005) Evacuated blood collection tube, thrombin/clot activator/gel separator ( SNOMED CT #702281005) yellow cap (unknown#yellow) 2 ml (Details: UCUM code mL = 'mL') handling
temperatureQualifier : Ambient temperature ()
temperatureRange : 15-25 °C
MaxDurations
Value Unit System Code 60 minute Unified Code for Units of Measure (UCUM) min handling
temperatureQualifier : Refrigerated temperature ()
temperatureRange : 2-8 °C
MaxDurations
Value Unit System Code 8 hour Unified Code for Units of Measure (UCUM) h
typeTested
type : Plasma specimen ( SNOMED CT #119361006)
preference : alternate
Containers
Material Type Cap MinimumVolume[x] glass ( SNOMED CT #32039001) Evacuated blood collection tube, thrombin/clot activator/gel separator ( SNOMED CT #702281005) green cap (unknown#green) 2 ml (Details: UCUM code mL = 'mL') rejectionCriterion : insufficient specimen volume ( RejectionCriterion #insufficient) , hemolized specimen ( RejectionCriterion #hemolized)
handling
temperatureQualifier : Ambient temperature ()
temperatureRange : 15-25 °C
MaxDurations
Value Unit System Code 60 minute Unified Code for Units of Measure (UCUM) min handling
temperatureQualifier : Refrigerated temperature ()
temperatureRange : 2-8 °C
MaxDurations
Value Unit System Code 8 hour Unified Code for Units of Measure (UCUM) h
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.