| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : No defined compartments |
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Device .
Resource Device "Nonin20601PulseOx"
identifier
:
System
Identifier:
00-1C-05-04-00-00-78-25,
Identifier: 00-1C-05-04-00-00-78-25,
Bluetooth
Address:
00-1C-05-00-78-25
Address: 00-1C-05-00-78-25
| DeviceIdentifier | Issuer | Jurisdiction | CarrierHRF | EntryType |
| 120343001125 | http://hl7.org/fhir/NamingSystem/gs1-di | http://hl7.org/fhir/NamingSystem/fda-udi | (01)120343001125(21)0400007825 | unknown |
manufacturer : Nonin Medical, Inc.
serialNumber : 0400007825
| Value | Type |
| Nonin_Medical_Inc._323552 | user-friendly-name |
modelNumber : Model 3150
type : MDC_MOC_VMS_MDS_SIMP: Personal Health Device ( ISO 11073-10101 Health informatics - Point-of-care #65573 "MDC_MOC_VMS_MDS_SIMP")
version
type : MDC_ID_PROD_SPEC_FW: Firmware revision ( ISO 11073-10101 Health informatics - Point-of-care #531976)
value : 0.9C
version
type : MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version ( ISO 11073-10101 Health informatics - Point-of-care #532352)
value : 1.0
| Specification | Version |
| MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter ( ISO 11073-10101 Health informatics - Point-of-care #528388) | 1 |
property
type : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list ( ISO 11073-10101 Health informatics - Point-of-care #532353)
value : 4 (ContinuaPAN#4)
property
type : regulation-status (ASN1ToHL7#532354.0)
value : Device is Regulated (v2-0136#N)
property
type : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol ( ISO 11073-10101 Health informatics - Point-of-care #68220)
value : MDC_TIME_SYNC_NONE: No time synchronization ( ISO 11073-10101 Health informatics - Point-of-care #532224)
property
type : mds-time-capab-real-time-clock (ASN1ToHL7#68219.0)
value : real time clock supported (v2-0136#Y)
property
type : mds-time-capab-set-clock (ASN1ToHL7#68219.2)
value : setting the time supported (v2-0136#Y)
property
type : mds-time-capab-relative-time (ASN1ToHL7#68219.2)
value : relative time supported (v2-0136#Y)
property
type : MDC_TIME_RES_ABS: Resolution of absolute time clock ( ISO 11073-10101 Health informatics - Point-of-care #68222)
value : 1000000 us (Details: UCUM code us = 'us')
property
type : MDC_TIME_RES_REL: Resolution of relative time clock ( ISO 11073-10101 Health informatics - Point-of-care #68222)
value : 1000000 us (Details: UCUM code us = 'us')
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.