| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : No defined compartments |
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Device .
Resource Device "Bodimetrics"
identifier
:
System
Identifier:
00-00-00-00-00-00-00-00,
Identifier: 00-00-00-00-00-00-00-00,
Bluetooth
Address:
00-17-E9-54-C8-52
Address: 00-17-E9-54-C8-52
| DeviceIdentifier | Issuer | Jurisdiction | CarrierHRF | EntryType |
| 102698895442 | http://hl7.org/fhir/NamingSystem/gs1-di | http://hl7.org/fhir/NamingSystem/fda-udi | (01)102698895442(21)1607124656 | unknown |
manufacturer : BodiMetrics
serialNumber : 1607124656
| Value | Type |
| BM-88 4656 | user-friendly-name |
modelNumber : 6611
type : MDC_MOC_VMS_MDS_SIMP: Personal Health Device ( ISO 11073-10101 Health informatics - Point-of-care #65573 "MDC_MOC_VMS_MDS_SIMP")
version
type : MDC_ID_PROD_SPEC_SW: Software revision ( ISO 11073-10101 Health informatics - Point-of-care #531975)
value : 020008
version
type : MDC_ID_PROD_SPEC_HW: Hardware revision ( ISO 11073-10101 Health informatics - Point-of-care #531974)
value : CC
conformsTo
specification : MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter ( ISO 11073-10101 Health informatics - Point-of-care #528391)
version : 1
conformsTo
specification : MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device ( ISO 11073-10101 Health informatics - Point-of-care #528457)
version : 1
conformsTo
specification : MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram ( ISO 11073-10101 Health informatics - Point-of-care #528390)
version : 1
conformsTo
specification : MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter ( ISO 11073-10101 Health informatics - Point-of-care #528388)
version : 1
conformsTo
specification : MDC_DEV_SPEC_PROFILE_TEMP: Thermometer ( ISO 11073-10101 Health informatics - Point-of-care #528392)
version : 1
| Type | Value[x] |
| MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol ( ISO 11073-10101 Health informatics - Point-of-care #68220) | MDC_TIME_SYNC_NONE: No time synchronization ( ISO 11073-10101 Health informatics - Point-of-care #532224) |
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.