This
page
is
part
of
the
FHIR
Specification
(v5.0.0:
R5
-
STU
v6.0.0-ballot1:
Release
6
Ballot
(1st
Draft)
(see
Ballot
Notes
).
This
is
the
The
current
published
version
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : No defined compartments |
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile Device .
Resource Device "ANDThermometer"
identifier
:
System
Identifier:
54-4A-16-FF-FE-32-12-26,
Identifier: 54-4A-16-FF-FE-32-12-26,
Bluetooth
Address:
54-4A-16-32-12-26
Address: 54-4A-16-32-12-26
| DeviceIdentifier | Issuer | Jurisdiction | CarrierHRF | EntryType |
| 92677176693286 | http://hl7.org/fhir/NamingSystem/gs1-di | http://hl7.org/fhir/NamingSystem/fda-udi | (01)92677176693286(21)5160800011 | unknown |
manufacturer : A&D Medical
serialNumber : 5160800011
| Value | Type |
| A&D_UT201BLEA_321226 | user-friendly-name |
modelNumber : UT-201BLE-A
type : MDC_MOC_VMS_MDS_SIMP: Personal Health Device ( ISO 11073-10101 Health informatics - Point-of-care #65573 "MDC_MOC_VMS_MDS_SIMP")
version
type : MDC_ID_PROD_SPEC_FW: Firmware revision ( ISO 11073-10101 Health informatics - Point-of-care #531976)
value : HTP009_137
version
type : MDC_ID_PROD_SPEC_SW: Software revision ( ISO 11073-10101 Health informatics - Point-of-care #531975)
value : 0.00
version
type : MDC_ID_PROD_SPEC_HW: Hardware revision ( ISO 11073-10101 Health informatics - Point-of-care #531974)
value : 0.00
version
type : MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version ( ISO 11073-10101 Health informatics - Point-of-care #532352)
value : 4.1
| Specification | Version |
| MDC_DEV_SPEC_PROFILE_TEMP: Thermometer ( ISO 11073-10101 Health informatics - Point-of-care #528392) | 1 |
property
type : MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list ( ISO 11073-10101 Health informatics - Point-of-care #532353)
value : 32776 (ContinuaPAN#32776)
property
type : regulation-status (ASN1ToHL7#532354.0)
value : Device is Regulated (v2-0136#N)
property
type : MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol ( ISO 11073-10101 Health informatics - Point-of-care #68220)
value : MDC_TIME_SYNC_NONE: No time synchronization ( ISO 11073-10101 Health informatics - Point-of-care #532224)
property
type : mds-time-capab-real-time-clock (ASN1ToHL7#68219.0)
value : real time clock supported (v2-0136#Y)
property
type : mds-time-capab-set-clock (ASN1ToHL7#68219.1)
value : setting the time supported (v2-0136#Y)
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.