This
page
is
part
of
the
FHIR
Specification
(v4.3.0:
R4B
-
STU
(v5.0.0-snapshot3:
R5
Snapshot
#3,
to
support
Connectathon
32
).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R4B
R4
R3
Security
Work
Group
|
Maturity
Level
:
|
|
Use
Context
:
|
Official
URL
:
http://hl7.org/fhir/ValueSet/object-lifecycle-events
|
|
|||
| draft as of 2017-02-20 |
|
|||
|
|
|
|||
This value set is used in the following places:
This FHIR value set is comprised of lifecycle event codes. The FHIR Actor value set is based on DICOM Audit Message, ParticipantObjectDataLifeCycle; ISO Standard, TS 21089-2017;
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle
This
expansion
generated
28
May
14
Dec
2022
This value set contains 42 concepts
Expansion based on:
| Code | System | Display | Definition |
1
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Origination / Creation |
|
2
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Import / Copy |
|
3
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Amendment |
|
4
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Verification |
|
5
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Translation |
|
6
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Access / Use |
|
7
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | De-identification |
|
8
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Aggregation / summarization / derivation |
|
9
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Report |
|
10
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Export |
|
11
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Disclosure |
|
12
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Receipt of disclosure |
|
13
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Archiving |
|
14
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Logical deletion |
|
15
|
http://terminology.hl7.org/CodeSystem/dicom-audit-lifecycle | Permanent erasure / Physical destruction |
|
access
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Access/View Record Lifecycle Event |
Occurs when an agent causes the system to obtain and open a record entry for inspection or review. |
hold
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Add Legal Hold Record Lifecycle Event |
Occurs when an agent causes the system to tag or otherwise indicate special access management and suspension of record entry deletion/destruction, if deemed relevant to a lawsuit or which are reasonably anticipated to be relevant or to fulfill organizational policy under the legal doctrine of “duty to preserve”. |
amend
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Amend (Update) Record Lifecycle Event |
Occurs when an agent makes any change to record entry content currently residing in storage considered permanent (persistent). |
archive
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Archive Record Lifecycle Event |
Occurs when an agent causes the system to create and move archive artifacts containing record entry content, typically to long-term offline storage. |
attest
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Attest Record Lifecycle Event |
Occurs when an agent causes the system to capture the agent’s digital signature (or equivalent indication) during formal validation of record entry content. |
decrypt
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Decrypt Record Lifecycle Event |
Occurs when an agent causes the system to decode record entry content from a cipher. |
deidentify
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | De-Identify (Anononymize) Record Lifecycle Event |
Occurs when an agent causes the system to scrub record entry content to reduce the association between a set of identifying data and the data subject in a way that might or might not be reversible. |
deprecate
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Deprecate Record Lifecycle Event |
Occurs when an agent causes the system to tag record entry(ies) as obsolete, erroneous or untrustworthy, to warn against its future use. |
destroy
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Destroy/Delete Record Lifecycle Event |
Occurs when an agent causes the system to permanently erase record entry content from the system. |
disclose
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Disclose Record Lifecycle Event |
Occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content. |
encrypt
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Encrypt Record Lifecycle Event |
Occurs when an agent causes the system to encode record entry content in a cipher. |
extract
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Extract Record Lifecycle Event |
Occurs when an agent causes the system to selectively pull out a subset of record entry content, based on explicit criteria. |
link
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Link Record Lifecycle Event |
Occurs when an agent causes the system to connect related record entries. |
merge
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Merge Record Lifecycle Event |
Occurs when an agent causes the system to combine or join content from two or more record entries, resulting in a single logical record entry. |
originate
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Originate/Retain Record Lifecycle Event |
Occurs when an agent causes the system to: a) initiate capture of potential record content, and b) incorporate that content into the storage considered a permanent part of the health record. |
pseudonymize
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Pseudonymize Record Lifecycle Event |
Occurs when an agent causes the system to remove record entry content to reduce the association between a set of identifying data and the data subject in a way that may be reversible. |
reactivate
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Re-activate Record Lifecycle Event |
Occurs when an agent causes the system to recreate or restore full status to record entries previously deleted or deprecated. |
receive
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Receive/Retain Record Lifecycle Event |
Occurs when an agent causes the system to a) initiate capture of data content from elsewhere, and b) incorporate that content into the storage considered a permanent part of the health record. |
reidentify
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Re-identify Record Lifecycle Event |
Occurs when an agent causes the system to restore information to data that allows identification of information source and/or information subject. |
unhold
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Remove Legal Hold Record Lifecycle Event |
Occurs when an agent causes the system to remove a tag or other cues for special access management had required to fulfill organizational policy under the legal doctrine of “duty to preserve”. |
report
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Report (Output) Record Lifecycle Event |
Occurs when an agent causes the system to produce and deliver record entry content in a particular form and manner. |
restore
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Restore Record Lifecycle Event |
Occurs when an agent causes the system to recreate record entries and their content from a previous created archive artefact. |
transform
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Transform/Translate Record Lifecycle Event |
Occurs when an agent causes the system to change the form, language or code system used to represent record entry content. |
transmit
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Transmit Record Lifecycle Event |
Occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another. |
unlink
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Unlink Record Lifecycle Event |
Occurs when an agent causes the system to disconnect two or more record entries previously connected, rendering them separate (disconnected) again. |
unmerge
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Unmerge Record Lifecycle Event |
Occurs when an agent causes the system to reverse a previous record entry merge operation, rendering them separate again. |
verify
|
http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle | Verify Record Lifecycle Event |
Occurs when an agent causes the system to confirm compliance of data or data objects with regulations, requirements, specifications, or other imposed conditions based on organizational policy. |
See the full registry of value sets defined as part of FHIR.
Explanation of the columns that may appear on this page:
| Lvl | A few code lists that FHIR defines are hierarchical - each code is assigned a level. For value sets, levels are mostly used to organize codes for user convenience, but may follow code system hierarchy - see Code System for further information |
| Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract') |
| Display | The display (used in the display element of a Coding ). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |