Release 4B Snapshot 3: Connectathon 32 Base

This page is part of the Snapshot #3 for FHIR Specification (v4.3.0: R4B - STU ). The current version which supercedes this version is 5.0.0 R5 , released to support Connectathon 32 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Schedule-provider-location2-example.json

Example Schedule/exampleloc2 (JSON)

Patient Administration Work Group Maturity Level : N/A Standards Status : Informative Compartments : Device , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Example 2 of a Schedule resource with a composite schedulable resource

{
  "resourceType": "Schedule",
  "id": "exampleloc2",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n      Dr. Beverly Crusher - Starfleet HQ Sickbay Schedule\n\t\t</div>"

  "resourceType" : "Schedule",
  "id" : "exampleloc2",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n      Dr. Beverly Crusher - Starfleet HQ Sickbay Schedule\n\t\t</div>"

  },
  "identifier": [
    {
      "use": "usual",
      "system": "http://example.org/scheduleid",
      "value": "47"
    }
  ],
  "active": true,
  "serviceCategory": [
    {
      "coding": [
        {
          "code": "31",
          "display": "Specialist Surgical"
        }
      ]
    }
  ],
  "serviceType": [
    {
      "coding": [
        {
          "code": "221",
          "display": "Surgery - General"
        }
      ]
    }
  ],
  "specialty": [
    {
      "coding": [
        {
          "code": "394610002",
          "display": "Surgery-Neurosurgery"
        }
      ]
    }
  ],
  "actor": [
    {
      "reference": "Practitioner/1",
      "display": "Dr. Beverly Crusher"
    },
    {
      "reference": "Location/2",
      "display": "Starfleet HQ Sickbay"

  "identifier" : [{
    "use" : "usual",
    "system" : "http://example.org/scheduleid",
    "value" : "47"
  }],
  "active" : true,
  "serviceCategory" : [{
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/service-category",
      "code" : "31",
      "display" : "Specialist Surgical"
    }]
  }],
  "serviceType" : [{
    "concept" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/service-type",
        "code" : "221",
        "display" : "Surgery - General"
      }]

    }
  ],
  "planningHorizon": {
    "start": "2017-12-25T09:15:00Z",
    "end": "2017-12-25T09:30:00Z"

  }],
  "specialty" : [{
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "394610002",
      "display" : "Surgery-Neurosurgery"
    }]
  }],
  "actor" : [{
    "reference" : "Practitioner/1",
    "display" : "Dr. Beverly Crusher"

  },
  "comment": "The slots attached to this schedule are for neurosurgery operations at Starfleet HQ only."

  {
    "reference" : "Location/2",
    "display" : "Starfleet HQ Sickbay"
  }],
  "planningHorizon" : {
    "start" : "2017-12-25T09:15:00Z",
    "end" : "2017-12-25T09:30:00Z"
  },
  "comment" : "The slots attached to this schedule are for neurosurgery operations at Starfleet HQ only."

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.