Release 4B Snapshot 3: Connectathon 32 Base

This page is part of the Snapshot #3 for FHIR Specification (v4.3.0: R4B - STU ). The current version which supercedes this version is 5.0.0 R5 , released to support Connectathon 32 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Detectedissue-example-dup.json

Example DetectedIssue/duplicate (JSON)

Clinical Decision Support Work Group Maturity Level : N/A Standards Status : Informative Compartments : Device , Patient , Practitioner

Raw JSON ( canonical form + also see JSON Format Specification )

Diagnostic order is placed when a recent image of the same body site already exists

{
  "resourceType": "DetectedIssue",
  "id": "duplicate",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n      <p>Similar test was performed within the past 14 days</p>\n      <ul>\n        <li>\n          <a href=\"ServiceRequest/id\">Chest CT - ordered May 8, 2013 by Dr. Adam Careful</a>\n        </li>\n        <li>\n          <a href=\"ImagingStudy/example\">Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20 AM</a>\n        </li>\n      </ul>\n    </div>"

  "resourceType" : "DetectedIssue",
  "id" : "duplicate",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n      <p>Similar test was performed within the past 14 days</p>\n      <ul>\n        <li>\n          <a href=\"ServiceRequest/id\">Chest CT - ordered May 8, 2013 by Dr. Adam Careful</a>\n        </li>\n        <li>\n          <a href=\"ImagingStudy/example\">Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20 AM</a>\n        </li>\n      </ul>\n    </div>"

  },
  "identifier": [
    {
      "use": "official",
      "system": "http://example.org",
      "value": "12345"
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-ActCode",
        "code": "DUPTHPY",
        "display": "Duplicate Therapy Alert"
      }
    ]

  "identifier" : [{
    "use" : "official",
    "system" : "http://example.org",
    "value" : "12345"
  }],
  "status" : "final",
  "code" : {
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/v3-ActCode",
      "code" : "DUPTHPY",
      "display" : "Duplicate Therapy Alert"
    }]

  },
  "patient": {
    "reference": "Patient/dicom"

  "subject" : {
    "reference" : "Patient/dicom"

  },
  "identifiedDateTime": "2013-05-08",
  "author": {
    "reference": "Device/software"

  "identifiedDateTime" : "2013-05-08",
  "author" : {
    "reference" : "Device/example"

  },
  "implicated": [
    {
      "reference": "ServiceRequest/di",
      "display": "Chest CT - ordered May 8, 2013 by Dr. Adam Careful"
    },
    {
      "reference": "ImagingStudy/example",
      "display": "Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20 AM"
    }
  ],
  "detail": "Similar test was performed within the past 14 days",
  "reference": "http://www.tmhp.com/RadiologyClinicalDecisionSupport/2011/CHEST%20IMAGING%20GUIDELINES%202011.pdf"

  "implicated" : [{
    "reference" : "ServiceRequest/di",
    "display" : "Chest CT - ordered May 8, 2013 by Dr. Adam Careful"
  },
  {
    "reference" : "ImagingStudy/example",
    "display" : "Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20 AM"
  }],
  "detail" : "Similar test was performed within the past 14 days",
  "reference" : "http://www.tmhp.com/RadiologyClinicalDecisionSupport/2011/CHEST%20IMAGING%20GUIDELINES%202011.pdf"

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.