This
page
is
part
of
the
FHIR
Specification
(v4.0.1:
R4
-
Mixed
Normative
and
STU
)
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
(v5.0.0-snapshot1:
Release
5
Snapshot
#1).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
R2
| Patient Care Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : Encounter , Patient , Practitioner , RelatedPerson |
Raw XML ( canonical form + also see XML Format Specification )
Example of a device manipulation (id = "example-implant")
<?xml version="1.0" encoding="UTF-8"?> <Procedure xmlns="http://hl7.org/fhir"> <id value="example-implant"/>(Details : {SNOMED CT code '25267002' = 'Insertion of intracardiac pacemaker', given as 'Insertion of intracardiac pacemaker (procedure)'})<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative</b> </p> <div> <p> Resource "example-implant" </p> </div> <p> <b> status</b> : completed</p> <p> <b> code</b> : Implant Pacemaker <span> (<a> SNOMED CT</a> #25267002 "Insertion of intracardiac pacemaker (procedure)")</span> </p> <p> <b> subject</b> : <a> Patient/example</a> "Peter CHALMERS"</p> <p> <b> occurrence</b> : 2015-04-05</p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a> Practitioner/example: Dr Cecil Surgeon</a> "Adam CAREFUL"</td> </tr> </table> <p> <b> followUp</b> : ROS 5 days - 2013-04-10 <span> ()</span> </p> <p> <b> note</b> : Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p> <h3> FocalDevices</h3> <table> <tr> <td> -</td> <td> <b> Action</b> </td> <td> <b> Manipulated</b> </td> </tr> <tr> <td> *</td> <td> Implanted <span> (<a> Procedure Device Action Codes</a> #implanted)</span> </td> <td> <a> </a> <blockquote> <div> <p> Resource "example-pacemaker" </p> </div> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> lotNumber</b> : 1234-5678</p> <p> <b> type</b> : Cardiac pacemaker implant <span> (<a> SNOMED CT</a> #14106009)</span> </p> <p> <b> subject</b> : <a> Patient/example</a> "Peter CHALMERS"</p> </blockquote> </td> </tr> </table> </div> </text> <contained> <Device> <id value="example-pacemaker"/> <manufacturer value="Acme Devices, Inc"/> <lotNumber value="1234-5678"/> <type> <coding> <system value="http://snomed.info/sct"/> <code value="14106009"/> <display value="Cardiac pacemaker implant"/> </coding> </type> <subject> <reference value="Patient/example"/> </subject> </Device> </contained> <status value="completed"/> <code> <coding> <system value="http://snomed.info/sct"/> <code value="25267002"/> <display value="Insertion of intracardiac pacemaker (procedure)"/> </coding> <text value="Implant Pacemaker"/> </code> <subject><reference value="Patient/example"/> </subject><occurrenceDateTime value="2015-04-05"/> <performer> <actor><reference value="Practitioner/example"/> <display value="Dr Cecil Surgeon"/> </actor> </performer><reason> <concept> <text value="Bradycardia"/> </concept> </reason> <followUp> <text value="ROS 5 days - 2013-04-10"/> </followUp> <note> <text value="Routine Appendectomy. Appendix was inflamed and in retro-caecal position"/> </note> <focalDevice> <action> <coding> <system value="http://hl7.org/fhir/device-action"/> <code value="implanted"/> </coding> </action> <manipulated><reference value="#example-pacemaker"/> </manipulated> </focalDevice> </ Procedure >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.