This
page
is
part
of
the
FHIR
Specification
(v4.0.1:
R4
-
Mixed
Normative
and
STU
)
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
(v5.0.0-snapshot1:
Release
5
Snapshot
#1).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
| Clinical Decision Support Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : Not linked to any defined compartments |
Raw JSON ( canonical form + also see JSON Format Specification )
Example of guidanceresponse
{
"resourceType": "GuidanceResponse",
"id": "example",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>contained</b>: </p><p><b>requestIdentifier</b>: guidanceRequest1</p><p><b>identifier</b>: guidanceResponse1</p><p><b>module</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a>Patient/example</a></p><p><b>encounter</b>: <a>Encounter/example</a></p><p><b>occurrenceDateTime</b>: 10/03/2017 4:02:00 PM</p><p><b>performer</b>: <a>Device/software</a></p><p><b>reasonCode</b>: Guideline Appropriate Ordering Assessment <span>(Details )</span></p><p><b>outputParameters</b>: id: outputParameters1</p></div>"
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div><p>Resource "example" </p></div><p><b>requestIdentifier</b>: id: guidanceRequest1</p><p><b>identifier</b>: id: guidanceResponse1</p><p><b>module</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a>Patient/example</a> "Peter CHALMERS"</p><p><b>encounter</b>: <a>Encounter/example</a></p><p><b>occurrenceDateTime</b>: 2017-03-10T16:02:00Z</p><p><b>performer</b>: <a>Device/software</a></p><p><b>outputParameters</b>: <a> </a></p><blockquote><div><p>Resource "outputParameters1" </p></div><blockquote><p><b>parameter</b></p><p><b>name</b>: score</p><p><b>value</b>: 7</p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: item-assessed</p><p><b>value</b>: CT, head, wo iv contrast <span> (<a>Current Procedural Terminology (CPT®)</a>#70450)</span></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: device</p><p><b>value</b>: <a>Device/software</a></p></blockquote><blockquote><p><b>parameter</b></p><p><b>name</b>: guideline-followed</p><p><b>value</b>: <a>http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p></blockquote></blockquote></div>"
},
"contained": [
{
"resourceType": "Parameters",
"id": "outputParameters1",
"parameter": [
{
"name": "score",
"valueDecimal": 7
},
{
"name": "item-assessed",
"valueCodeableConcept": {
"coding": [
{
"system": "http://www.ama-assn.org/go/cpt",
"code": "70450",
"display": "CT, head, wo iv contrast"
}
]
}
},
{
"name": "device",
"valueReference": {
"reference": "Device/software"
}
},
{
"name": "guideline-followed",
"valueUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"
}
]
}
],
"requestIdentifier": {
"system": "http://example.org",
"value": "guidanceRequest1"
},
"identifier": [
{
"system": "http://example.org",
"value": "guidanceResponse1"
}
],
"moduleUri": "http://someguidelineprovider.org/radiology-appropriateness-guidelines.html",
"status": "success",
"subject": {
"reference": "Patient/example"
},
"encounter": {
"reference": "Encounter/example"
},
"occurrenceDateTime": "2017-03-10T16:02:00Z",
"performer": {
"reference": "Device/software"
},
"reasonCode": [
"reason": [
{
"text": "Guideline Appropriate Ordering Assessment"
"concept": {
"text": "Guideline Appropriate Ordering Assessment"
}
}
],
"outputParameters": {
"reference": "#outputParameters1"
}
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.