Release 4B R5 Final QA

This page is part of the FHIR Specification (v4.3.0: R4B (v5.0.0-draft-final: Final QA Preview for R5 - STU see ballot notes ). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Observationdefinition-example

Example ObservationDefinition/example (Narrative)

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Not linked to any defined compartments

This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile ObservationDefinition .


Generated Narrative Narrative: ObservationDefinition

Resource ObservationDefinition "example"

status : active

category : Laboratory ( Observation Category Codes #laboratory)

code : Glucose [Moles/volume] Albumin/Protein.total in Blood Serum or Plasma by Electrophoresis ( LOINC #15074-8) #13980-8)

permittedDataType : Quantity

multipleResultsAllowed : false

method : Total measurement ( SNOMED CT #115341008)

preferredReportName : Serum albumin/​Protein total

QuantitativeDetails

- Unit DecimalPrecision
* % ( UCUM #%) 0

qualifiedValue

context : Normal Range ( Observation Reference Range Meaning Codes #normal)

rangeCategory : reference

range : 50-?

qualifiedValue

context : Normal Range ( Observation Reference Range Meaning Codes #normal)

rangeCategory : critical

range : ?-40


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.