Diagnostics
This
page
is
part
of
the
FHIR
Specification
(v4.3.0:
R4B
(v5.0.0-draft-final:
Final
QA
Preview
for
R5
-
STU
see
ballot
notes
).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
R2
| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : Device , Encounter , Patient , Practitioner , RelatedPerson |
Raw JSON ( canonical form + also see JSON Format Specification )
Real-world patient -base excess
{
"resourceType": "Observation",
"id": "f002",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource "f002" </p></div><p><b>identifier</b>: id: 6324 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Base excess in Blood by calculation <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#11555-0)</span></p><p><b>subject</b>: <a href=\"patient-f001.html\">Patient/f001: P. van de Heuvel</a> "Pieter VAN DE HEUVEL"</p><p><b>effective</b>: 2013-04-02T10:30:10+01:00 --> 2013-04-05T10:30:10+01:00</p><p><b>issued</b>: 04/04/2013 1:30:10 AM</p><p><b>performer</b>: <a href=\"practitioner-f005.html\">Practitioner/f005: A. Langeveld</a> "Langeveld ANNE"</p><p><b>value</b>: 12.6 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mmol/L = 'mmol/L')</span></p><p><b>interpretation</b>: High <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#H)</span></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>7.1 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mmol/L = 'mmol/L')</span></td><td>11.2 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mmol/L = 'mmol/L')</span></td></tr></table></div>"
},
"identifier": [
{
"use": "official",
"system": "http://www.bmc.nl/zorgportal/identifiers/observations",
"value": "6324"
}
],
"status": "final",
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "11555-0",
"display": "Base excess in Blood by calculation"
}
]
"resourceType" : "Observation",
"id" : "f002",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"f002\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation "f002" </p></div><p><b>identifier</b>: <span title=\" urn:oid:2.16.840.1.113883.4.642.1.7 &#10; 2.16.840.1.113883.4.642.1.118 \">id: 6324 (use: OFFICIAL)</span></p><p><b>status</b>: final</p><p><b>code</b>: Base excess in Blood by calculation <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#11555-0)</span></p><p><b>subject</b>: <a href=\"patient-example-f001-pieter.html\">Patient/f001: P. van de Heuvel</a> "Pieter VAN DE HEUVEL"</p><p><b>effective</b>: 2013-04-02T10:30:10+01:00</p><p><b>issued</b>: 4 Apr 2013, 1:30:10 am</p><p><b>performer</b>: <a href=\"practitioner-example-f005-al.html\">Practitioner/f005: A. Langeveld</a> "Langeveld ANNE"</p><p><b>value</b>: 12.6 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mmol/L = 'mmol/L')</span></p><p><b>interpretation</b>: High <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#H)</span></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>7.1 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mmol/L = 'mmol/L')</span></td><td>11.2 mmol/l<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mmol/L = 'mmol/L')</span></td></tr></table></div>"
},
"subject": {
"reference": "Patient/f001",
"display": "P. van de Heuvel"
"identifier" : [{
"use" : "official",
"system" : "http://www.bmc.nl/zorgportal/identifiers/observations",
"value" : "6324"
}],
"status" : "final",
"code" : {
"coding" : [{
"system" : "http://loinc.org",
"code" : "11555-0",
"display" : "Base excess in Blood by calculation"
}]
},
"effectivePeriod": {
"start": "2013-04-02T10:30:10+01:00",
"end": "2013-04-05T10:30:10+01:00"
"subject" : {
"reference" : "Patient/f001",
"display" : "P. van de Heuvel"
},
"issued": "2013-04-03T15:30:10+01:00",
"performer": [
{
"reference": "Practitioner/f005",
"display": "A. Langeveld"
}
],
"valueQuantity": {
"value": 12.6,
"unit": "mmol/l",
"system": "http://unitsofmeasure.org",
"code": "mmol/L"
"effectiveDateTime" : "2013-04-02T10:30:10+01:00",
"issued" : "2013-04-03T15:30:10+01:00",
"performer" : [{
"reference" : "Practitioner/f005",
"display" : "A. Langeveld"
}],
"valueQuantity" : {
"value" : 12.6,
"unit" : "mmol/l",
"system" : "http://unitsofmeasure.org",
"code" : "mmol/L"
},
"interpretation": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code": "H",
"display": "High"
}
]
}
],
"referenceRange": [
{
"low": {
"value": 7.1,
"unit": "mmol/l",
"system": "http://unitsofmeasure.org",
"code": "mmol/L"
},
"high": {
"value": 11.2,
"unit": "mmol/l",
"system": "http://unitsofmeasure.org",
"code": "mmol/L"
}
"interpretation" : [{
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code" : "H",
"display" : "High"
}]
}],
"referenceRange" : [{
"low" : {
"value" : 7.1,
"unit" : "mmol/l",
"system" : "http://unitsofmeasure.org",
"code" : "mmol/L"
},
"high" : {
"value" : 11.2,
"unit" : "mmol/l",
"system" : "http://unitsofmeasure.org",
"code" : "mmol/L"
}
]
}]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
Release
4B
(v4.3.0)
hl7.fhir.r4b.core#4.3.0
R5
hl7.fhir.core#5.0.0-draft-final
generated
on
Sat,
May
28,
2022
12:56+1000.
Wed,
Mar
1,
2023
23:07+1100.
Links:
Search
|
Version
History
|
Table
of
Contents
|
Glossary
|
QA
Page
|
Compare
to
R4
R4B
|
Compare
to
R5
Draft
|
|
Propose
a
change