Release 4B R5 Final QA

This page is part of the FHIR Specification (v4.3.0: R4B (v5.0.0-draft-final: Final QA Preview for R5 - STU see ballot notes ). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-bloodpressure-cancel.json

Example Observation/blood-pressure-cancel (JSON)

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Device , Encounter , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Blood Pressure Measurement cancelled

{
  "resourceType": "Observation",
  "id": "blood-pressure-cancel",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/vitalsigns"
    ]

  "resourceType" : "Observation",
  "id" : "blood-pressure-cancel",
  "meta" : {
    "profile" : ["http://hl7.org/fhir/StructureDefinition/vitalsigns"]

  },
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource &quot;blood-pressure-cancel&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"vitalsigns.html\">Vital Signs Profile</a></p></div><p><b>identifier</b>: id: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</p><p><b>status</b>: cancelled</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Blood pressure systolic &amp; diastolic <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#85354-9 &quot;Blood pressure panel with all children optional&quot;)</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> &quot;Peter CHALMERS&quot;</p><p><b>effective</b>: 2012-09-17</p><p><b>performer</b>: <a href=\"practitioner-example.html\">Practitioner/example</a> &quot;Adam CAREFUL&quot;</p><p><b>interpretation</b>: Below low normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#L &quot;low&quot;)</span></p><p><b>note</b>: In this example, the blood pressure measurements are not available due to cancellation of the order.  Data absent reason is present for each component</p><p><b>bodySite</b>: Right arm <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#368209003)</span></p><blockquote><p><b>component</b></p><p><b>code</b>: Systolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8480-6; <a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#271649006; clinical-codes#bp-s &quot;Systolic Blood pressure&quot;)</span></p><p><b>dataAbsentReason</b>: Not Asked <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-data-absent-reason.html\">DataAbsentReason</a>#not-asked)</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8462-4)</span></p><p><b>dataAbsentReason</b>: Not Asked <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-data-absent-reason.html\">DataAbsentReason</a>#not-asked)</span></p></blockquote></div>"

  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"blood-pressure-cancel\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation &quot;blood-pressure-cancel&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"vitalsigns.html\">Vital Signs Profile</a></p></div><p><b>identifier</b>: <span title=\" \tEH  Narrative created by build\n\t&lt;text&gt;\n\t\t&lt;status value=&quot;generated&quot;/&gt;\n\t\t&lt;div xmlns=&quot;http://www.w3.org/1999/xhtml&quot;&gt;Sept 17, 2012: Systolic Blood pressure 107/60 mmHg (low)&lt;/div&gt;\n\t&lt;/text&gt;\n \">id: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</span></p><p><b>status</b>: cancelled</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Blood pressure systolic &amp; diastolic <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#85354-9 &quot;Blood pressure panel with all children optional&quot;)</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> &quot;Peter CHALMERS&quot;</p><p><b>effective</b>: 2012-09-17</p><p><b>performer</b>: <a href=\"practitioner-example.html\">Practitioner/example</a> &quot;Adam CAREFUL&quot;</p><p><b>interpretation</b>: <span title=\"  an interpretation offered to the combination observation\n        generally, it would only be appropriate to offer an interpretation\n        of an observation that has no value if it has &quot;COMP&quot; (component)\n        observations  \">Below low normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#L &quot;low&quot;)</span></span></p><p><b>note</b>: In this example, the blood pressure measurements are not available due to cancellation of the order.  Data absent reason is present for each component</p><p><b>bodySite</b>: <span title=\"  for an observation with components, these cannot disagree with the flags on the components  \">Right arm <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#368209003)</span></span></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\" \n           Observations are often coded in multiple code systems.\n           - LOINC provides a very specific code (though not usefully more specific in this particular case)\n           - snomed provides a clinically relevant code that is usually less granular than LOINC\n           - the source system provides its own code, which may be less or more granular than LOINC\n\t this instance shows the concept. The other codes only have a LOINC code  \">Systolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8480-6; <a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#271649006; clinical-codes#bp-s &quot;Systolic Blood pressure&quot;)</span></span></p><p><b>dataAbsentReason</b>: <span title=\"  no value due to some error\n    &lt;valueQuantity&gt;\n      &lt;value value=&quot;107&quot;/&gt;\n      &lt;unit value=&quot;mm[Hg]&quot;/&gt;\n    &lt;/valueQuantity&gt;\n \">Not Asked <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-data-absent-reason.html\">DataAbsentReason</a>#not-asked)</span></span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8462-4)</span></p><p><b>dataAbsentReason</b>: <span title=\"  no value due to some error\n    &lt;valueQuantity&gt;\n      &lt;value value=&quot;60&quot;/&gt;\n      &lt;unit value=&quot;mm[Hg]&quot;/&gt;\n    &lt;/valueQuantity&gt;\n \">Not Asked <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/4.0.0/CodeSystem-data-absent-reason.html\">DataAbsentReason</a>#not-asked)</span></span></p></blockquote></div>"

  },
  "identifier": [
    {
      "system": "urn:ietf:rfc:3986",
      "value": "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281"
    }
  ],
  "status": "cancelled",
  "category": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/observation-category",
          "code": "vital-signs",
          "display": "Vital Signs"
        }
      ]
    }
  ],
  "code": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "85354-9",
        "display": "Blood pressure panel with all children optional"
      }
    ],
    "text": "Blood pressure systolic & diastolic"

  "identifier" : [{
    "system" : "urn:ietf:rfc:3986",
    "value" : "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281"
  }],
  "status" : "cancelled",
  "category" : [{
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/observation-category",
      "code" : "vital-signs",
      "display" : "Vital Signs"
    }]
  }],
  "code" : {
    "coding" : [{
      "system" : "http://loinc.org",
      "code" : "85354-9",
      "display" : "Blood pressure panel with all children optional"
    }],
    "text" : "Blood pressure systolic & diastolic"

  },
  "subject": {
    "reference": "Patient/example"

  "subject" : {
    "reference" : "Patient/example"

  },
  "effectiveDateTime": "2012-09-17",
  "performer": [
    {
      "reference": "Practitioner/example"
    }
  ],
  "interpretation": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
          "code": "L",
          "display": "low"
        }
      ],
      "text": "Below low normal"
    }
  ],
  "note": [
    {
      "text": "In this example, the blood pressure measurements are not available due to cancellation of the order.  Data absent reason is present for each component"
    }
  ],
  "bodySite": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "368209003",
        "display": "Right arm"
      }
    ]

  "effectiveDateTime" : "2012-09-17",
  "performer" : [{
    "reference" : "Practitioner/example"
  }],
  "interpretation" : [{
    "coding" : [{
      "system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
      "code" : "L",
      "display" : "low"
    }],
    "text" : "Below low normal"
  }],
  "note" : [{
    "text" : "In this example, the blood pressure measurements are not available due to cancellation of the order.  Data absent reason is present for each component"
  }],
  "bodySite" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "368209003",
      "display" : "Right arm"
    }]

  },
  "component": [
    {
      "code": {
        "coding": [
          {
            "system": "http://loinc.org",
            "code": "8480-6",
            "display": "Systolic blood pressure"
          },
          {
            "system": "http://snomed.info/sct",
            "code": "271649006",
            "display": "Systolic blood pressure"
          },
          {
            "system": "http://acme.org/devices/clinical-codes",
            "code": "bp-s",
            "display": "Systolic Blood pressure"
          }
        ]

  "component" : [{
    "code" : {
      "coding" : [{
        "system" : "http://loinc.org",
        "code" : "8480-6",
        "display" : "Systolic blood pressure"

      },
      "dataAbsentReason": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/data-absent-reason",
            "code": "not-asked",
            "display": "Not Asked"
          }
        ]
      }
    },
    {
      "code": {
        "coding": [
          {
            "system": "http://loinc.org",
            "code": "8462-4",
            "display": "Diastolic blood pressure"
          }
        ]

      {
        "system" : "http://snomed.info/sct",
        "code" : "271649006",
        "display" : "Systolic blood pressure"

      },
      "dataAbsentReason": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/data-absent-reason",
            "code": "not-asked",
            "display": "Not Asked"
          }
        ]
      }

      {
        "system" : "http://acme.org/devices/clinical-codes",
        "code" : "bp-s",
        "display" : "Systolic Blood pressure"
      }]
    },
    "dataAbsentReason" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/data-absent-reason",
        "code" : "not-asked",
        "display" : "Not Asked"
      }]

    }
  ]

  },
  {
    "code" : {
      "coding" : [{
        "system" : "http://loinc.org",
        "code" : "8462-4",
        "display" : "Diastolic blood pressure"
      }]
    },
    "dataAbsentReason" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/data-absent-reason",
        "code" : "not-asked",
        "display" : "Not Asked"
      }]
    }
  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.