Release 4B R5 Final QA

This page is part of the FHIR Specification (v4.3.0: R4B (v5.0.0-draft-final: Final QA Preview for R5 - STU see ballot notes ). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Diagnosticreport-example-ultrasound.json

Example DiagnosticReport/ultrasound (JSON)

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Device , Encounter , Patient , Practitioner

Raw JSON ( canonical form + also see JSON Format Specification )

Abdominal Ultrasound example

{
  "resourceType": "DiagnosticReport",
  "id": "ultrasound",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2><span title=\"Codes: {http://snomed.info/sct 45036003}\">Abdominal Ultrasound</span> (<span title=\"Codes: {http://snomed.info/sct 394914008}, {http://terminology.hl7.org/CodeSystem/v2-0074 RAD}\">Radiology</span>) </h2><table class=\"grid\"><tr><td>Subject</td><td><b>Jim </b> male, DoB: 1974-12-25 ( Medical record number: 12345 (USUAL))</td></tr><tr><td>When For</td><td>2012-12-01T12:00:00+01:00</td></tr><tr><td>Reported</td><td>2012-12-01T12:00:00+01:00</td></tr></table><p><b>Report Details</b></p><p>Unremarkable study</p></div>"

  "resourceType" : "DiagnosticReport",
  "id" : "ultrasound",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><h2><span title=\"Codes: {http://snomed.info/sct 45036003}\">Abdominal Ultrasound</span> (<span title=\"Codes: {http://snomed.info/sct 394914008}, {http://terminology.hl7.org/CodeSystem/v2-0074 RAD}\">Radiology</span>) </h2><table class=\"grid\"><tr><td>Subject</td><td><b>Jim </b> male, DoB: 1974-12-25 ( Medical record number: 12345 (use: USUAL, period: 2001-05-06 --&gt; (ongoing)))</td></tr><tr><td>When For</td><td>2012-12-01T12:00:00+01:00</td></tr><tr><td>Reported</td><td>2012-12-01T12:00:00+01:00</td></tr></table><p><b>Report Details</b></p><div><p>Unremarkable study</p>\n</div></div>"

  },
  "status": "final",
  "category": [

  "status" : "final",
  "category" : [{
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "394914008",
      "display" : "Radiology"
    },

    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "394914008",
          "display": "Radiology"
        },
        {
          "system": "http://terminology.hl7.org/CodeSystem/v2-0074",
          "code": "RAD"
        }
      ]
    }
  ],
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "45036003",
        "display": "Ultrasonography of abdomen"
      }
    ],
    "text": "Abdominal Ultrasound"

      "system" : "http://terminology.hl7.org/CodeSystem/v2-0074",
      "code" : "RAD"
    }]
  }],
  "code" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "45036003",
      "display" : "Ultrasonography of abdomen"
    }],
    "text" : "Abdominal Ultrasound"

  },
  "subject": {
    "reference": "Patient/example"

  "subject" : {
    "reference" : "Patient/example"

  },
  "effectiveDateTime": "2012-12-01T12:00:00+01:00",
  "issued": "2012-12-01T12:00:00+01:00",
  "performer": [
    {
      "reference": "Practitioner/example"
    }
  ],
  "media": [
    {
      "comment": "A comment about the image",
      "link": {
        "reference": "Media/1.2.840.11361907579238403408700.3.1.04.19970327150033",
        "display": "WADO example image"
      }

  "effectiveDateTime" : "2012-12-01T12:00:00+01:00",
  "issued" : "2012-12-01T12:00:00+01:00",
  "performer" : [{
    "reference" : "Practitioner/example"
  }],
  "media" : [{
    "comment" : "A comment about the image",
    "link" : {
      "reference" : "DocumentReference/1.2.840.11361907579238403408700.3.1.04.19970327150033",
      "display" : "WADO example image"

    }
  ],
  "conclusion": "Unremarkable study"

  }],
  "conclusion" : "Unremarkable study"

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.