This
page
is
part
of
the
FHIR
Specification
(v4.0.1:
R4
-
Mixed
Normative
and
STU
)
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
(v4.2.0:
R5
Preview
#1).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
| Orders and Observations Work Group | Maturity Level : N/A | Standards Status : Informative | Compartments : Not linked to any defined compartments |
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .
Generated Narrative with Details
id : 2364
status : active
typeCollected : Venous blood specimen (Details : {SNOMED CT code '122555007' = 'Venous blood specimen', given as 'Venous blood specimen'})
patientPreparation : 12 hour fasting (Details ) , At rest (Details : {SNOMED CT code '263678003' = 'At rest', given as 'At rest'})
timeAspect : preferrably morning time
typeTested
type : Serum specimen (Details : {SNOMED CT code '119364003' = 'Serum specimen', given as 'Serum specimen'})
preference : preferred
Containers
- Material Type Cap MinimumVolume[x] * plastic (Details : {SNOMED CT code '61088005' = 'Plastic', given as 'plastic'}) Evacuated blood collection tube, thrombin/clot activator/gel separator (Details : {SNOMED CT code '702281005' = 'Evacuated blood collection tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube, thrombin/clot activator/gel separator'}) yellow cap (Details : {urn:iso:std:iso:6710:2017 code 'yellow' = 'yellow', given as 'yellow cap'}) 2 ml (Details: UCUM code mL = 'mL') handling
temperatureQualifier : Ambient temperature (Details )
temperatureRange : 15-25 °C
maxDuration : 60 minute (Details: UCUM code min = 'min')
handling
temperatureQualifier : Refrigerated temperature (Details )
temperatureRange : 2-8 °C
maxDuration : 8 hour (Details: UCUM code h = 'h')
typeTested
type : Plasma specimen (Details : {SNOMED CT code '119361006' = 'Plasma specimen', given as 'Plasma specimen'})
preference : alternate
Containers
- Material Type Cap MinimumVolume[x] * glass (Details : {SNOMED CT code '32039001' = 'Glass', given as 'glass'}) Evacuated blood collection tube with heparin lithium and geltube, thrombin/clot activator/gel separator (Details : {SNOMED CT code'767390000''702281005' = 'Evacuated blood collectiontube with heparin lithium and geltube, thrombin/clot activator/gel separator', given as 'Evacuated blood collectiontube with heparin lithium and geltube, thrombin/clot activator/gel separator'})green cap (Details : {urn:iso:std:iso:6710:2017 code 'green' = 'green', given as 'green cap'}) 2 ml (Details: UCUM code mL = 'mL') rejectionCriterion : insufficient specimen volume (Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'insufficient' = 'insufficient specimen volume', given as 'insufficient specimen volume'}) , hemolized specimen (Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'hemolized' = 'hemolized specimen', given as 'hemolized specimen'})
handling
temperatureQualifier : Ambient temperature (Details )
temperatureRange : 15-25 °C
maxDuration : 60 minute (Details: UCUM code min = 'min')
handling
temperatureQualifier : Refrigerated temperature (Details )
temperatureRange : 2-8 °C
maxDuration : 8 hour (Details: UCUM code h = 'h')
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.