Release 4 5 Preview #1

This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always be available at this URL). (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Specimendefinition-example-serum-plasma

Orders and Observations Work Group Maturity Level : N/A Standards Status : Informative Compartments : Not linked to any defined compartments

This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .


Generated Narrative with Details

id : 2364

status : active

typeCollected : Venous blood specimen (Details : {SNOMED CT code '122555007' = 'Venous blood specimen', given as 'Venous blood specimen'})

patientPreparation : 12 hour fasting (Details ) , At rest (Details : {SNOMED CT code '263678003' = 'At rest', given as 'At rest'})

timeAspect : preferrably morning time

typeTested

type : Serum specimen (Details : {SNOMED CT code '119364003' = 'Serum specimen', given as 'Serum specimen'})

preference : preferred

Containers

- Material Type Cap MinimumVolume[x]
* plastic (Details : {SNOMED CT code '61088005' = 'Plastic', given as 'plastic'}) Evacuated blood collection tube, thrombin/clot activator/gel separator (Details : {SNOMED CT code '702281005' = 'Evacuated blood collection tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube, thrombin/clot activator/gel separator'}) yellow cap (Details : {urn:iso:std:iso:6710:2017 code 'yellow' = 'yellow', given as 'yellow cap'}) 2 ml (Details: UCUM code mL = 'mL')

handling

temperatureQualifier : Ambient temperature (Details )

temperatureRange : 15-25 °C

maxDuration : 60 minute (Details: UCUM code min = 'min')

handling

temperatureQualifier : Refrigerated temperature (Details )

temperatureRange : 2-8 °C

maxDuration : 8 hour (Details: UCUM code h = 'h')

typeTested

type : Plasma specimen (Details : {SNOMED CT code '119361006' = 'Plasma specimen', given as 'Plasma specimen'})

preference : alternate

Containers

- Material Type Cap MinimumVolume[x]
* glass (Details : {SNOMED CT code '32039001' = 'Glass', given as 'glass'}) Evacuated blood collection tube with heparin lithium and gel tube, thrombin/clot activator/gel separator (Details : {SNOMED CT code '767390000' '702281005' = 'Evacuated blood collection tube with heparin lithium and gel tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube with heparin lithium and gel tube, thrombin/clot activator/gel separator'}) green cap (Details : {urn:iso:std:iso:6710:2017 code 'green' = 'green', given as 'green cap'}) 2 ml (Details: UCUM code mL = 'mL')

rejectionCriterion : insufficient specimen volume (Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'insufficient' = 'insufficient specimen volume', given as 'insufficient specimen volume'}) , hemolized specimen (Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'hemolized' = 'hemolized specimen', given as 'hemolized specimen'})

handling

temperatureQualifier : Ambient temperature (Details )

temperatureRange : 15-25 °C

maxDuration : 60 minute (Details: UCUM code min = 'min')

handling

temperatureQualifier : Refrigerated temperature (Details )

temperatureRange : 2-8 °C

maxDuration : 8 hour (Details: UCUM code h = 'h')


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.