Page
versions:
R4
R3
R2
Orders
and
Observations
Work
Group
|
Maturity Level : N/A | Standards Status : Informative |
| Extensions : | |
| observation-bodyPosition |
bodyPosition
:
The position of the body when the observation was done, e.g. standing, sitting. To be used only when the body position in not precoordinated in the observation code. |
| observation-delta |
delta
:
The qualitative change in the value relative to the previous measurement. Usually only recorded if the change is clinically significant. |
| observation-focusCode |
focusCode
:
A
code
representing
the
focus
of
an
observation
when
the
focus
is
not
the
patient
of
record.
In
other
words,
the
focus
of
the
observation
is
different
from
|
| observation-timeOffset |
timeOffset
:
A
specific
offset
time
in
milliseconds
from
the
stated
time
in
the
Observation.appliesDateTime
to
allow
for
representation
of
sequential
recording
of
sampled
data
from
the
same
lead
or
data
stream.
For
example,
an
ECG
recorder
may
record
sequentially
3
leads
four
time
to
receive
12-lead
ECG,
see
ISO
22077
|
| observation-sequelTo |
sequelTo
:
This observation follows the target observation (e.g. timed tests such as Glucose Tolerance Test). |
| observation-replaces |
replaces
:
This observation replaces a previous observation (i.e. a revised value). |
| observation-gatewayDevice |
gatewayDevice
:
The Provenance/AuditEvent resources can represent the same information. Note that the Provenance/AuditEvent resources can represent the same information. |
| observation-specimenCode |
specimenCode
:
A
code
representing
the
the
type
of
specimen
used
for
this
observation.
Should
only
be
used
if
not
implicit
in
the
code
found
in
|
| observation-deviceCode |
deviceCode
:
A
code
representing
the
the
type
of
device
used
for
this
observation.
Should
only
be
used
if
not
implicit
in
the
code
found
in
|
| observation-precondition |
precondition
:
Other preceding or concurrent observations that must be known to correctly interpret the the observation. For example an fiO2 measure taken alongside of a SpO2 measurement. See the Observation notes section for additional guidance. |
| observation-reagent |
reagent
:
Reference to reagents used to generate this observation. This is intended for this for in-lab transactions between instruments and Laboratory Information Systems (LIS). |
| observation-secondaryFinding |
secondaryFinding
:
Secondary
findings
are
genetic
test
results
that
provide
information
about
variants
in
a
gene
unrelated
to
the
primary
purpose
for
the
testing,
most
often
discovered
when
Whole
Exome
Sequencing
(WES)
For more detail, please see: https://ghr.nlm.nih.gov/primer/testing/secondaryfindings. |