This
page
is
part
of
the
FHIR
Specification
(v3.0.2:
STU
3).
(v3.5.0:
R4
Ballot
#2).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
| Imaging Integration Work Group | Maturity Level : N/A | Ballot Status : Informative | Compartments : Patient |
Raw XML ( canonical form + also see XML Format Specification )
Example XR imaging study with full elements (id = "example-xr")
<?xml version="1.0" encoding="UTF-8"?> <ImagingStudy xmlns="http://hl7.org/fhir"> <id value="example-xr"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml">XR Wrist 3+ Views. John Smith (MRN: 09236). Accession: W12342398. Performed: 2017-01-01. 1 series, 2 images.</div> </text><identifier> <use value="official"/> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430046"/> </identifier> <identifier> <use value="usual"/> <type> <coding><system value="http://terminology.hl7.org/CodeSystem/v2-0203"/> <code value="ACSN"/> </coding></type> <value value="W12342398"/> <assigner> <reference value="Organization/dicom-organization"/></assigner> </identifier> <identifier> <use value="secondary"/> <value value="55551234"/> <assigner> <reference value="Organization/dicom-organization"/> </assigner> </identifier><status value="available"/> <modality> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="DX"/> </modality> <subject> <reference value="Patient/dicom"/> </subject> <context> <reference value="Encounter/example"/> </context> <started value="2017-01-01T11:01:20+03:00"/> <basedOn><reference value="ServiceRequest/example"/> </basedOn> <referrer> <reference value="Practitioner/example"/> </referrer> <interpreter> <reference value="Practitioner/example"/> </interpreter> <endpoint> <reference value="Endpoint/example-wadors"/> </endpoint> <numberOfSeries value="1"/> <numberOfInstances value="2"/> <procedureReference> <reference value="Procedure/example"/> </procedureReference> <procedureCode> <coding> <system value="http://www.radlex.org"/> <code value="RPID2589"/> <display value="XR Wrist 3+ Views"/> </coding> <text value="XR Wrist 3+ Views"/> </procedureCode><reasonCode> <coding> <system value="http://snomed.info/sct"/> <code value="357009"/> <display value="Closed fracture of trapezoidal bone of wrist"/></coding> </reasonCode> <note> <text value="XR Wrist 3+ Views"/> </note> <series><identifier> <use value="official"/> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430045.1"/> </identifier> <number value="3"/> <modality> <system value="http://dicom.nema.org/resources/ontology/DCM"/> <code value="DX"/> </modality> <description value="XR Wrist 3+ Views"/> <numberOfInstances value="2"/><endpoint> <reference value="Endpoint/example-wadors"/> </endpoint> <bodySite> <!-- Added body site to support duplicate checking example --> <system value="http://snomed.info/sct"/> <code value="T-15460"/> <display value="Wrist Joint"/> </bodySite> <laterality> <system value="http://snomed.info/sct"/> <code value="419161000"/> <display value="Unilateral left"/> </laterality> <started value="2011-01-01T11:01:20+03:00"/> <performer><function> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationType"/> <code value="PRF"/> </coding> </function> <actor> <reference value="Practitioner/example"/> </actor> </performer> <instance><identifier> <use value="official"/> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430045.1.1"/> </identifier> <number value="1"/><sopClass> <system value="urn:ietf:rfc:3986"/> <code value="urn:oid:1.2.840.10008.5.1.4.1.1.2"/> </sopClass> <title value="PA VIEW"/> </instance> <instance><identifier> <use value="official"/> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.124.113543.6003.1154777499.30246.19789.3503430045.1.2"/> </identifier> <number value="2"/><sopClass> <system value="urn:ietf:rfc:3986"/> <code value="urn:oid:1.2.840.10008.5.1.4.1.1.2"/> </sopClass> <title value="LL VIEW"/> </instance> </series> </ ImagingStudy >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.