FHIR Release 3 (STU) R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.0.2: STU 3). (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3

4.2.12.807 4.3.13.114 Code System http://hl7.org/fhir/adverse-event-category http://terminology.hl7.org/CodeSystem/adverse-event-category

Vocabulary Patient Care Work Group   Maturity Level : 0 Informative Trial Use Use Context : Any

This is a code system defined by the FHIR project.

Summary

Defining URL: http://hl7.org/fhir/adverse-event-category http://terminology.hl7.org/CodeSystem/adverse-event-category
Version: 3.5.0
Name: AdverseEventCategory
Title: AdverseEventCategory
Definition:

Overall categorization of the event, e.g. real product related or potential situational.

Committee: Regulated Clinical Research Information Management Patient Care Work Group
OID: 2.16.840.1.113883.4.642.1.807 2.16.840.1.113883.4.642.1.1251 (for OID based terminology systems)
Source Resource XML / JSON

This Code system is used in the following value sets:

  • ValueSet: AdverseEventCategory (Overall categorization of the event, e.g. real product related or potential) situational.)

Overall categorization of the event, e.g. real product related or potential situational.

This code system http://hl7.org/fhir/adverse-event-category http://terminology.hl7.org/CodeSystem/adverse-event-category defines the following codes:

Lvl Code Display Definition
AE 1 product-problem Adverse Event Product Problem
PAE 1 product-quality Potential Adverse Event Product Quality
1 product-use-error Product Use Error
2   wrong-dose Wrong Dose
2   incorrect-prescribing-information Incorrect Prescribing Information
2   wrong-technique Wrong Technique
2   wrong-route-of-administration Wrong Route of Administration
2   wrong-rate Wrong Rate
2   wrong-duration Wrong Duration
2   wrong-time Wrong Time
2   expired-drug Expired Drug
1 medical-device-use-error Medical Device Use Error
1 problem-different-manufacturer Problem with Different Manufacturer of Same Medicine
1 unsafe-physical-environment Unsafe Physical Environment

 

See the full registry of value sets code systems defined as part of FHIR.


Explanation of the columns that may appear on this page:

Level Lvl A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies See Code System for further information.
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding ). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code