FHIR Release 3 (STU) R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.0.2: STU 3). (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

4.2.12.193 4.2.13.203 Code System http://hl7.org/fhir/reference-handling-policy

Vocabulary FHIR Infrastructure Work Group   Maturity Level : 3 Informative Normative Use Context : Any

Normative Candidate Note: This page is candidate normative content for R4 in the Conformance Package . Once normative, it will lose it's Maturity Level, and breaking changes will no longer be made.

This is a code system defined by the FHIR project.

Summary

Defining URL: http://hl7.org/fhir/reference-handling-policy
Name: ReferenceHandlingPolicy
Definition:

A set of flags that defines how references are supported.

Committee: FHIR Infrastructure Work Group
OID: 2.16.840.1.113883.4.642.1.193 2.16.840.1.113883.4.642.1.203 (for OID based terminology systems)
Source Resource XML / JSON

This Code system is used in the following value sets:

A set of flags that defines how references are supported.

This code system http://hl7.org/fhir/reference-handling-policy defines the following codes:

Code Display Definition
literal Literal References The server supports and populates Literal references where they are known (this code does not guarantee that all references are literal; see 'enforced')
logical Logical References The server allows logical references
resolves Resolves References The server will attempt to resolve logical references to literal references (if resolution fails, the server may still accept resources; see logical)
enforced Reference Integrity Enforced The server enforces that references have integrity - e.g. it ensures that references can always be resolved. This is typically the case for clinical record systems, but often not the case for middleware/proxy systems
local Local References Only The server does not support references that point to other servers

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

Level Lvl A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies See Code System for further information.
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding ). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code