This page is part of the FHIR Specification (v1.6.0:
STU
3 Ballot 4). The current version which supercedes this version is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
. For a full list of available versions, see the
Directory of published versions
.
Page
versions:
. Page versions:
R5
R4B
R4
R3
R2
Raw JSON
(
canonical
form
canonical form
)
Definition
for
Value
SetProcedure
Device
Action
Codes
)
Definition for Value SetProcedure Device Action Codes
{
"resourceType": "ValueSet",
"id": "device-action",
"meta": {
"lastUpdated": "2015-10-24T07:41:03.495+11:00",
"lastUpdated": "2016-08-11T17:02:54.322+10:00",
"profile": [
"http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"
]
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
},
"extension": [
"url": "http://hl7.org/fhir/ValueSet/device-action",
"identifier": [
{
"url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
"valueUri": "urn:oid:2.16.840.1.113883.4.642.2.236"
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:2.16.840.1.113883.4.642.2.236"
}
],
"url": "http://hl7.org/fhir/ValueSet/device-action",
"version": "1.0.2",
"version": "1.6.0",
"name": "Procedure Device Action Codes",
"status": "draft",
"experimental": true,
"publisher": "FHIR Project team",
"contact": [
{
"telecom": [
{
"system": "other",
"value": "http://hl7.org/fhir"
}
]
}
],
"date": "2015-10-24T07:41:03+11:00",
"date": "2016-08-11T17:02:54+10:00",
"description": "Example value set for Procedure Device Action code (what happened to a device during a procedure.",
"codeSystem": {
"fhir_comments": [
" due to the lack of any available codes, we invent our own examples here "
],
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
"valueUri": "urn:oid:2.16.840.1.113883.4.642.1.236"
}
],
"system": "http://hl7.org/fhir/device-action",
"caseSensitive": true,
"concept": [
{
"code": "implanted",
"display": "Implanted",
"definition": "The device was implanted in the patient during the procedure."
},
{
"code": "explanted",
"display": "Explanted",
"definition": "The device was explanted from the patient during the procedure."
},
"compose": {
"include": [
{
"code": "manipulated",
"display": "Manipulated",
"definition": "The device remains in that patient, but its location, settings, or functionality was changed."
"system": "http://hl7.org/fhir/device-action"
}
]
}
}
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.
©
HL7.org
2011+.
FHIR
DSTU2
(v1.0.2-7202)
generated
on
Sat,
Oct
24,
2015
07:42+1100.
Links:
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.