DSTU2 STU 3 Ballot
This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is

This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . For a full list of available versions, see the Directory of published versions . Page versions: . Page versions: R5 R4B R4 R3 R2

Valueset-device-action.json Raw JSON (

Raw JSON ( canonical form canonical form ) Definition for Value SetProcedure Device Action Codes )

Definition for Value SetProcedure Device Action Codes

{
  "resourceType": "ValueSet",
  "id": "device-action",
  "meta": {
    "lastUpdated": "2015-10-24T07:41:03.495+11:00",

    "lastUpdated": "2016-08-11T17:02:54.322+10:00",

    "profile": [
      "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"
    ]
  },
  "text": {
    "status": "generated",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "extension": [

  "url": "http://hl7.org/fhir/ValueSet/device-action",
  "identifier": [

    {
      "url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
      "valueUri": "urn:oid:2.16.840.1.113883.4.642.2.236"

      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:2.16.840.1.113883.4.642.2.236"

    }
  ],
  "url": "http://hl7.org/fhir/ValueSet/device-action",
  "version": "1.0.2",

  "version": "1.6.0",

  "name": "Procedure Device Action Codes",
  "status": "draft",
  "experimental": true,
  "publisher": "FHIR Project team",
  "contact": [
    {
      "telecom": [
        {
          "system": "other",
          "value": "http://hl7.org/fhir"
        }
      ]
    }
  ],
  "date": "2015-10-24T07:41:03+11:00",

  "date": "2016-08-11T17:02:54+10:00",

  "description": "Example value set for Procedure Device Action code (what happened to a device during a procedure.",
  "codeSystem": {
    "fhir_comments": [
      "   due to the lack of any available codes, we invent our own examples here   "
    ],
    "extension": [
      {
        "url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
        "valueUri": "urn:oid:2.16.840.1.113883.4.642.1.236"
      }
    ],
    "system": "http://hl7.org/fhir/device-action",
    "caseSensitive": true,
    "concept": [
      {
        "code": "implanted",
        "display": "Implanted",
        "definition": "The device was implanted in the patient during the procedure."
      },
      {
        "code": "explanted",
        "display": "Explanted",
        "definition": "The device was explanted from the patient during the procedure."
      },

  "compose": {
    "include": [

      {
        "code": "manipulated",
        "display": "Manipulated",
        "definition": "The device remains in that patient, but its location, settings, or functionality was changed."

        "system": "http://hl7.org/fhir/device-action"

      }
    ]
  }
}
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.
©
HL7.org
2011+.
FHIR
DSTU2
(v1.0.2-7202)
generated
on
Sat,
Oct
24,
2015
07:42+1100.
Links:

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.