This page is part of the FHIR Specification (v1.6.0:
STU
)
in
it's
permanent
home
(it
will
always
be
available
at
this
URL).
The
current
version
which
supercedes
this
version
is
3 Ballot 4). The current version which supercedes this version is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
. For a full list of available versions, see the
Directory of published versions
.
Page
versions:
. Page versions:
R5
R4B
R4
Servicerequest-example-ambulation.json
Orders
and
Observations
Work
Group
Maturity
Level
:
N/A
Standards
Status
:
Informative
Compartments
:
Device
,
Encounter
,
Patient
,
Practitioner
,
RelatedPerson
R3
Raw
JSON
(
canonical
form
+
also
see
JSON
Format
Specification
)
Example
of
an
order
for
anambulation
procedure
{
"resourceType": "ServiceRequest",
"id": "ambulation",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: ambulation</p><p><b>identifier</b>: 45678</p><p><b>basedOn</b>: <a>Maternity care plan</a></p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>code</b>: Ambulation <span>(Details : {SNOMED CT code '62013009' = 'Ambulating patient', given as 'Ambulating patient (procedure)'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>authoredOn</b>: 05/03/2017</p><p><b>requester</b>: <a>Dr. Beverly Crusher</a></p><p><b>reasonReference</b>: <a>Blood Pressure</a></p></div>"
},
"identifier": [
{
"value": "45678"
}
],
"basedOn": [
{
"reference": "CarePlan/preg",
"display": "Maternity care plan"
}
],
"status": "completed",
"intent": "order",
"code": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "62013009",
"display": "Ambulating patient (procedure)"
}
],
"text": "Ambulation"
},
"subject": {
"reference": "Patient/example"
},
"authoredOn": "2017-03-05",
"requester": {
"reference": "Practitioner/3ad0687e-f477-468c-afd5-fcc2bf897809",
"display": "Dr. Beverly Crusher"
},
"reasonReference": [
{
"reference": "Observation/blood-pressure",
"display": "Blood Pressure"
}
]
}
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.
®©
HL7.org
2011+.
FHIR
Release
4
(Technical
Correction
#1)
(v4.0.1)
generated
on
Fri,
Nov
1,
2019
09:36+1100.
QA
Page
Links:
Ambulance provided by Burgers Healthcare
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Location/amb> a fhir:Location;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "amb"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\">Mobile Clinic</div>"
];
fhir:Location.status [ fhir:value "active"];
fhir:Location.name [ fhir:value "BUMC Ambulance"];
fhir:Location.description [ fhir:value "Ambulance provided by Burgers University Medical Center"];
fhir:Location.mode [ fhir:value "kind"];
fhir:Location.type [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v3/RoleCode" ];
fhir:Coding.code [ fhir:value "AMB" ];
fhir:Coding.display [ fhir:value "Ambulance" ]
]
];
fhir:Location.telecom [
fhir:index 0;
fhir:ContactPoint.system [ fhir:value "phone" ];
fhir:ContactPoint.value [ fhir:value "2329" ];
fhir:ContactPoint.use [ fhir:value "mobile" ]
];
fhir:Location.physicalType [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/location-physical-type" ];
fhir:Coding.code [ fhir:value "ve" ];
fhir:Coding.display [ fhir:value "Vehicle" ]
]
];
fhir:Location.managingOrganization [
fhir:link <http://hl7.org/fhir/Organization/f001>;
fhir:Reference.reference [ fhir:value "Organization/f001" ]
] .
<http://hl7.org/fhir/Organization/f001> a fhir:Organization .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.