DSTU2 STU 3 Candidate
This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . For a full list of available versions, see the Directory of published versions . Page versions: . Page versions: R5 R4B R4 R3 R2

Specimen-example.json Raw JSON (

Raw JSON ( canonical form canonical form ) General Specimen Example )

General Specimen Example

{
  "resourceType": "Specimen",
  "id": "101",
  "text": {
    "fhir_comments": [
      "  text>\n    <status value=\"generated\" />\n    <div xmlns=\"http://www.w3.org/1999/xhtml\">[Put rendering here]</div>\n  </text>  "
    ],
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: 101</p><p><b>contained</b>: </p><p><b>identifier</b>: 23234352356</p><p><b>status</b>: available</p><p><b>type</b>: Venous blood specimen <span>(Details : {SNOMED CT code '122555007' = '122555007', given as 'Venous blood specimen'})</span></p><p><b>subject</b>: <a>Peter Patient</a></p><p><b>accessionIdentifier</b>: X352356</p><p><b>receivedTime</b>: 04/03/2011 6:03:00 PM</p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Comment</b></td><td><b>Collected[x]</b></td><td><b>Quantity</b></td><td><b>Method</b></td></tr><tr><td>*</td><td><a>Practitioner/example</a></td><td>Specimen is grossly lipemic</td><td>30/05/2011 4:15:00 PM</td><td>6 mL</td><td>Line, Venous <span>(Details : {http://hl7.org/fhir/v2/0488 code 'LNV' = 'Line, Venous)</span></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Identifier</b></td><td><b>Description</b></td><td><b>Type</b></td><td><b>Capacity</b></td><td><b>SpecimenQuantity</b></td><td><b>Additive[x]</b></td></tr><tr><td>*</td><td>48736-15394-75465</td><td>Green Gel tube</td><td>Vacutainer <span>(Details )</span></td><td>10 mL</td><td>6 mL</td><td>id: hep; Lithium/Li Heparin <span>(Details : {http://hl7.org/fhir/v3/EntityCode code 'HEPL' = 'Lithium/Li Heparin)</span></td></tr></table></div>"

    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: 101</p><p><b>contained</b>: </p><p><b>identifier</b>: 23234352356</p><p><b>accessionIdentifier</b>: X352356</p><p><b>status</b>: available</p><p><b>type</b>: Venous blood specimen <span>(Details : {SNOMED CT code '122555007' = 'Venous blood specimen (specimen)', given as 'Venous blood specimen'})</span></p><p><b>subject</b>: <a>Peter Patient</a></p><p><b>receivedTime</b>: 04/03/2011 6:03:00 PM</p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Comment</b></td><td><b>Collected[x]</b></td><td><b>Quantity</b></td><td><b>Method</b></td></tr><tr><td>*</td><td><a>Practitioner/example</a></td><td>Specimen is grossly lipemic</td><td>30/05/2011 4:15:00 PM</td><td>6 mL</td><td>Line, Venous <span>(Details : {http://hl7.org/fhir/v2/0488 code 'LNV' = 'Line, Venous)</span></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Identifier</b></td><td><b>Description</b></td><td><b>Type</b></td><td><b>Capacity</b></td><td><b>SpecimenQuantity</b></td><td><b>Additive[x]</b></td></tr><tr><td>*</td><td>48736-15394-75465</td><td>Green Gel tube</td><td>Vacutainer <span>(Details )</span></td><td>10 mL</td><td>6 mL</td><td>id: hep; Lithium/Li Heparin <span>(Details : {http://hl7.org/fhir/v3/EntityCode code 'HEPL' = 'Lithium/Li Heparin)</span></td></tr></table></div>"

  },
  "contained": [
    {
      "resourceType": "Substance",
      "id": "hep",
      "code": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/v3/EntityCode",
            "code": "HEPL"
          }
        ]
      }
    }
  ],
  "identifier": [
    {
      "fhir_comments": [
        "   a specimen identifier - e.g. assigned when the specimen was taken\n     this is often not done   "
      ],

      "system": "http://ehr.acme.org/identifiers/collections",
      "_system": {
        "fhir_comments": [
          "   a specimen identifier - e.g. assigned when the specimen was taken this is often not done   "
        ]
      },

      "value": "23234352356"
    }
  ],
  "status": "available",
  "_status": {
    "fhir_comments": [
      "  status is really about the specimen availability and includes the concepts available - The physical specimen is present and in good condition entered-in-error - The specimen was entered in error and therefore nullified. unavailable - There is no physical specimen because it is either lost, destroyed or consumed. unsatisfactory - The specimen cannot be used because of either a quality issue such as a broken container, contamination, or too old.  "
    ]

  "accessionIdentifier": {
    "system": "http://lab.acme.org/specimens/2011",
    "value": "X352356"

  },
  "status": "available",

  "type": {
    "fhir_comments": [
      "  \n   Type is a loosely defined field because there is such a lot of variation in how it is used.\n   The principal variation is how much information that could be represented elsewhere is also \n   represented here. For instance, here's some possible types:\n     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)\n     transfusion bag of blood (+ container.type) \n     Peritoneal lavage        (+ collection.bodySite)\n   If the type includes other fields, it would be normal not to populate the other fields\n\n   Note that this practice is so widespread that it's pointless to try and stop it   "
    ],

    "coding": [
      {
        "fhir_comments": [
          "  \n   Type is a loosely defined field because there is such a lot of variation in how it is used.\n   The principal variation is how much information that could be represented elsewhere is also\n   represented here. For instance, here's some possible types:\n     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)\n     transfusion bag of blood (+ container.type)\n     Peritoneal lavage        (+ collection.bodySite)\n   If the type includes other fields, it would be normal not to populate the other fields\n\n   Note that this practice is so widespread that it's pointless to try and stop it   "
        ],

        "system": "http://snomed.info/sct",
        "code": "122555007",
        "display": "Venous blood specimen"
      }
    ]
  },
  "subject": {
    "reference": "Patient/example",
    "display": "Peter Patient"
  },
  "accessionIdentifier": {
    "fhir_comments": [
      "   accession identifier - e.g. assigned by the labaratory when it is received.\n     This is common, unlike specimen identifier   "
    ],
    "system": "http://lab.acme.org/specimens/2011",
    "value": "X352356"
  },

  "receivedTime": "2011-03-04T07:03:00Z",
  "collection": {
    "collector": {
      "reference": "Practitioner/example"

      "reference": "Practitioner/example",
      "_reference": {
        "fhir_comments": [
          "   in practice, collecter is almost always recorded   "
        ]
      }

    },
    "comment": [
      "Specimen is grossly lipemic"
    ],

    "comment": "Specimen is grossly lipemic",

    "collectedDateTime": "2011-05-30T06:15:00Z",
    "_collectedDateTime": {
      "fhir_comments": [
        "   the time of collection is usually required. Usually a point in time, but can be a period \n      (collectedPeriod) if it's a timed collection (e.g. a 24 hour urine)   "
      ]
    },
    "quantity": {
      "fhir_comments": [
        "   e.g. full   "
      ],
      "value": 6,
      "unit": "mL"
    },
    "method": {
      "fhir_comments": [
        "   method is usually implied by type   "
      ],
      "coding": [
        {
          "system": "http://hl7.org/fhir/v2/0488",
          "code": "LNV"
        }
      ]
    }
  },
  "container": [
    {
      "identifier": [
        {
          "fhir_comments": [
            "   \n      the container identifier is not the same as the specimen identifier\n      usually, it is pre-printed/implanted etc.on the container prior to \n      use. It might a RFID in the container, or it might be a UDI \n      (http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/) \n      "
          ],
          "value": "48736-15394-75465",
          "_value": {
            "fhir_comments": [
              "   this is a serial number off the tube - there's no context such as a system   "
            ]
          }
        }
      ],
      "description": "Green Gel tube",
      "type": {
        "text": "Vacutainer",
        "_text": {
          "fhir_comments": [
            "   again, this might easily be used to cover additives and capacity as well   "
          ]
        }
      },
      "capacity": {
        "value": 10,
        "unit": "mL"
      },
      "specimenQuantity": {
        "fhir_comments": [
          "   if there's only one container, then this value is the same \n     as .collection.quantity (usually). This is for when there is more\n     than one container   "
        ],
        "value": 6,
        "unit": "mL"
      },
      "additiveReference": {
        "reference": "#hep"
      }
    }
  ]
}
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.
©
HL7.org
2011+.
FHIR
DSTU2
(v1.0.2-7202)
generated
on
Sat,
Oct
24,
2015
07:44+1100.
Links: