DSTU2 STU 3 Candidate
This page is part of the FHIR Specification (v1.0.2: DSTU 2). The current version which supercedes this version is

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see the Directory of published versions . For a full list of available versions, see the Directory of published versions . Page versions: . Page versions: R5 R4B R4 R3 R2

Specimen-example-urine.json Raw JSON (

Raw JSON ( canonical form canonical form ) VMA, Random Urine Sample )

VMA, Random Urine Sample

{
  "resourceType": "Specimen",
  "id": "vma-urine",
  "text": {
    "fhir_comments": [
      "  text>\n    <status value=\"generated\" />\n    <div xmlns=\"http://www.w3.org/1999/xhtml\">[Put rendering here]</div>\n  </text>  ",
      "  \n   Type is a loosely defined field because there is such a lot of variation in how it is used.\n   The principal variation is how much information that could be represented elsewhere is also \n   represented here. For instance, here's some possible types:\n     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)\n     transfusion bag of blood (+ container.type) \n     Peritoneal lavage        (+ collection.bodySite)\n   If the type includes other fields, it would be normal not to populate the other fields\n\n   Note that this practice is so widespread that it's pointless to try and stop it   "
    ],

    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: vma-urine</p><p><b>status</b>: available</p><p><b>type</b>: Urine, Random <span>(Details : {http://hl7.org/fhir/v2/0487 code 'RANDU' = 'Urine, Random', given as 'Urine, Random'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>accessionIdentifier</b>: X352356</p><p><b>receivedTime</b>: 18/08/2015 5:03:00 PM</p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td><a>Practitioner/f202</a></td><td>18/08/2015 5:03:00 PM</td></tr></table><h3>Treatments</h3><table><tr><td>-</td><td><b>Description</b></td><td><b>Procedure</b></td></tr><tr><td>*</td><td>Acidify to pH &lt; 3.0 with 6 N HCl.</td><td>Acidification <span>(Details : {http://hl7.org/fhir/v2/0373 code 'ACID' = 'Acidification)</span></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>Capacity</b></td><td><b>SpecimenQuantity</b></td></tr><tr><td>*</td><td>Non-sterile specimen container <span>(Details )</span></td><td>50 mls</td><td>10 mls</td></tr></table></div>"

    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: vma-urine</p><p><b>accessionIdentifier</b>: X352356</p><p><b>status</b>: available</p><p><b>type</b>: Urine, Random <span>(Details : {http://hl7.org/fhir/v2/0487 code 'RANDU' = 'Urine, Random', given as 'Urine, Random'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>receivedTime</b>: 18/08/2015 5:03:00 PM</p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td><a>Practitioner/f202</a></td><td>18/08/2015 5:03:00 PM</td></tr></table><h3>Treatments</h3><table><tr><td>-</td><td><b>Description</b></td><td><b>Procedure</b></td></tr><tr><td>*</td><td>Acidify to pH &lt; 3.0 with 6 N HCl.</td><td>Acidification <span>(Details : {http://hl7.org/fhir/v2/0373 code 'ACID' = 'Acidification)</span></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>Capacity</b></td><td><b>SpecimenQuantity</b></td></tr><tr><td>*</td><td>Non-sterile specimen container <span>(Details )</span></td><td>50 mls</td><td>10 mls</td></tr></table></div>"
  },
  "accessionIdentifier": {
    "system": "http://lab.acme.org/specimens/2015",
    "_system": {
      "fhir_comments": [
        "   accession identifier - e.g. assigned by the labaratory when it is received.\n     This is common, unlike specimen identifier   "
      ]
    },
    "value": "X352356"

  },
  "status": "available",
  "type": {
    "coding": [
      {
        "fhir_comments": [
          "  \n   Type is a loosely defined field because there is such a lot of variation in how it is used.\n   The principal variation is how much information that could be represented elsewhere is also\n   represented here. For instance, here's some possible types:\n     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)\n     transfusion bag of blood (+ container.type)\n     Peritoneal lavage        (+ collection.bodySite)\n   If the type includes other fields, it would be normal not to populate the other fields\n\n   Note that this practice is so widespread that it's pointless to try and stop it\n   "
        ],

        "system": "http://hl7.org/fhir/v2/0487",
        "code": "RANDU",
        "display": "Urine, Random"
      }
    ]
  },
  "subject": {
    "reference": "Patient/example"
  },
  "accessionIdentifier": {
    "fhir_comments": [
      "   accession identifier - e.g. assigned by the labaratory when it is received.\n     This is common, unlike specimen identifier   "
    ],
    "system": "http://lab.acme.org/specimens/2015",
    "value": "X352356"
  },

  "receivedTime": "2015-08-18T07:03:00Z",
  "collection": {
    "fhir_comments": [
      "   method is usually implied by type   "
    ],
    "collector": {
      "reference": "Practitioner/f202"

      "reference": "Practitioner/f202",
      "_reference": {
        "fhir_comments": [
          "   in practice, collecter is almost always recorded   "
        ]
      }

    },
    "collectedDateTime": "2015-08-18T07:03:00Z",
    "_collectedDateTime": {
      "fhir_comments": [
        "   the time of collection is usually required. Usually a point in time, but can be a period \n      (collectedPeriod) if it's a timed collection (e.g. a 24 hour urine)   "
      ]
    }
  },
  "treatment": [
    {
      "description": "Acidify to pH < 3.0 with 6 N HCl.",
      "procedure": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/v2/0373",
            "code": "ACID"
          }
        ]
      }
    }
  ],
  "container": [
    {
      "type": {
        "text": "Non-sterile specimen container"
      },
      "capacity": {
        "value": 50,
        "unit": "mls"
      },
      "specimenQuantity": {
        "value": 10,
        "unit": "mls"
      }
    }
  ]
}
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.
©
HL7.org
2011+.
FHIR
DSTU2
(v1.0.2-7202)
generated
on
Sat,
Oct
24,
2015
07:44+1100.
Links:

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.