This page is part of the FHIR Specification (v1.4.0:
STU
3 Ballot 3). The current version which supercedes this version is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
. For a full list of available versions, see the
Directory of published versions
.
Page
versions:
. Page versions:
R5
R4B
R4
R3
R2
Raw JSON
(
canonical
form
canonical form
)
Specimen
Reject
Example
)
Specimen Reject Example
{
"resourceType": "Observation",
"id": "unsat",
"text": {
"fhir_comments": [
" urn:oid:2.16.840.1.113883.4.642.1.7 ",
" 2.16.840.1.113883.4.642.1.118 "
],
"status": "generated",
"div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: unsat</p><p><b>identifier</b>: 6323 (OFFICIAL)</p><p><b>status</b>: cancelled</p><p><b>code</b>: Glucose [Moles/volume] in Blood <span>(Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose [Moles/volume] in Blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 9:30:10 AM --> 05/04/2013 9:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>dataAbsentReason</b>: Specimen unsatisfactory for evaluation <span>(Details : {SNOMED CT code '125154007' = '125154007', given as 'Specimen unsatisfactory for evaluation'})</span></p><p><b>comments</b>: Tube broken in transit and sample leaked</p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>3.1 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = '??')</span></td><td>6.2 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = '??')</span></td></tr></table></div>"
"div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: unsat</p><p><b>identifier</b>: 6323 (OFFICIAL)</p><p><b>status</b>: cancelled</p><p><b>code</b>: Glucose [Moles/volume] in Blood <span>(Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose [Moles/volume] in Blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 9:30:10 AM --> 05/04/2013 9:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>dataAbsentReason</b>: Specimen unsatisfactory for evaluation <span>(Details : {SNOMED CT code '125154007' = 'Specimen unsatisfactory for evaluation (finding)', given as 'Specimen unsatisfactory for evaluation'})</span></p><p><b>comment</b>: Tube broken in transit and sample leaked</p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>3.1 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = 'mmol/L')</span></td><td>6.2 mmol/l<span> (Details: http://unitsofmeasure.org code mmol/L = 'mmol/L')</span></td></tr></table></div>"
},
"identifier": [
{
"use": "official",
"system": "http://www.bmc.nl/zorgportal/identifiers/observations",
"value": "6323"
}
],
"status": "cancelled",
"code": {
"coding": [
{
"system": "http://loinc.org",
"code": "15074-8",
"display": "Glucose [Moles/volume] in Blood"
}
]
},
"subject": {
"reference": "Patient/f001",
"display": "P. van de Heuvel"
},
"effectivePeriod": {
"start": "2013-04-02T09:30:10+01:00",
"end": "2013-04-05T09:30:10+01:00"
},
"issued": "2013-04-03T15:30:10+01:00",
"performer": [
{
"reference": "Practitioner/f005",
"display": "A. Langeveld"
}
],
"dataAbsentReason": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "125154007",
"display": "Specimen unsatisfactory for evaluation"
}
]
},
"comments": "Tube broken in transit and sample leaked",
"comment": "Tube broken in transit and sample leaked",
"referenceRange": [
{
"low": {
"value": 3.1,
"unit": "mmol/l",
"system": "http://unitsofmeasure.org",
"code": "mmol/L"
},
"high": {
"value": 6.2,
"unit": "mmol/l",
"system": "http://unitsofmeasure.org",
"code": "mmol/L"
}
}
]
}
Usage
note:
every
effort
has
been
made
to
ensure
that
the
examples
are
correct
and
useful,
but
they
are
not
a
normative
part
of
the
specification.
©
HL7.org
2011+.
FHIR
DSTU2
(v1.0.2-7202)
generated
on
Sat,
Oct
24,
2015
07:44+1100.
Links:
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.