This page is part of the FHIR Specification (v1.4.0:
STU
3 Ballot 3). The current version which supercedes this version is
5.0.0
.
For
a
full
list
of
available
versions,
see
the
Directory
of
published
versions
. For a full list of available versions, see the
Directory of published versions
.
Page
versions:
. Page versions:
R5
R4B
R4
R3
R2
Raw XML
(
canonical
form
canonical form
)
Real-world
patient
-
CO2
(id
=
"f203")
)
Real-world patient - CO2 (id = "f203")
<Observation xmlns="http://hl7.org/fhir"> <id value="f203"/> <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f203</p><p><b>identifier</b>: 1304-03720-Bicarbonate</p><p><b>status</b>: final</p><p><b>code</b>: Bicarbonate [Moles/?volume] in Serum <span>(Details : {LOINC code '1963-8' = 'Bicarbonate [Moles/volume] in Serum', given as 'Bicarbonate[Moles/?volume] in Serum'}; {SNOMED CT code '365722008' = '365722008', given as 'Bicarbonate level'})(Details : {SNOMED CT code '166698001' = '166698001', given as 'Serum bicarbonate level normal'}; {http://hl7.org/fhir/v2/0078 code 'N' = 'Normal)(Details : {http://hl7.org/fhir/referencerange-meaning code 'normal' = 'Normal Range',[Moles/?volume] in Serum'}; {SNOMED CT code '365722008' = 'Finding of bicarbonate level (finding)', given as 'Bicarbonate level'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>issued</b>: 04/04/2013 2:34:00 PM</p><p><b>performer</b>: <a>Luigi Maas</a></p><p><b>value</b>: 28 mmol/L<span> (Details: SNOMED CT code 258813002 = 'Millimole/liter (qualifier value)')</span></p><p><b>interpretation</b>: Serum bicarbonate level normal <span>(Details : {SNOMED CT code '166698001' = 'Serum bicarbonate level normal (finding)', given as 'Serum bicarbonate level normal'}; {http://hl7.org/fhir/v2/0078 code 'N' = 'Normal)</span></p><p><b>method</b>: enzymatic method <span>(Details )</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td><td><b>Meaning</b></td></tr><tr><td>*</td><td>22</td><td>29</td><td>Normal Range <span>(Details : {http://hl7.org/fhir/referencerange-meaning code 'normal' = 'Normal Range', given as 'Normal Range'})</span></td></tr></table></div></text><identifier> <system value="https://intranet.aumc.nl/labvalues"/> <!-- Does not exist --> <value value="1304-03720-Bicarbonate"/> </identifier> <!-- Bicarbonate was measured on April fourth --> <status value="final"/> <code> <!-- Kind of observation = Bicarbonate LOINC and SNOMED CT translations here - Note in the US the primary code will be LOINC per meaningful use. Further SNOMED CT has acceeded to LOINC being the primary coding system for vitals and anthropromorphic measures. SNOMED CT is required in some countries such as the UK. --> <coding> <system value="http://loinc.org"/> <code value="1963-8"/> <display value="Bicarbonate [Moles/?volume] in Serum"/> </coding> <coding> <system value="http://snomed.info/sct"/> <code value="365722008"/> <display value="Bicarbonate level"/> </coding> </code> <subject> <reference value="Patient/f201"/> <display value="Roel"/> </subject> <issued value="2013-04-04T14:34:00+01:00"/> <performer> <reference value="Practitioner/f202"/> <display value="Luigi Maas"/> </performer> <valueQuantity> <!-- Bicarbonate=28mmol/L --> <value value="28"/> <unit value="mmol/L"/> <system value="http://snomed.info/sct"/> <code value="258813002"/> </valueQuantity> <interpretation> <coding> <system value="http://snomed.info/sct"/> <code value="166698001"/> <display value="Serum bicarbonate level normal"/> </coding> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="N"/> </coding> </interpretation> <!-- The observation is complete --> <!-- No reliability concerns --> <method> <!-- Method was enzymatic method --> <text value="enzymatic method"/> </method> <referenceRange> <!-- Healthy bicarbonate level ranges from 22mmol/L to 29mmol/L --> <low> <value value="22"/> </low> <high> <value value="29"/> </high> <meaning> <coding> <system value="http://hl7.org/fhir/referencerange-meaning"/> <code value="normal"/> <display value="Normal Range"/> </coding> </meaning> </referenceRange> </ Observation >Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification. © HL7.org 2011+. FHIR DSTU2 (v1.0.2-7202) generated on Sat, Oct 24, 2015 07:43+1100. Links:
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.