This
page
is
part
of
the
FHIR
Specification
(v3.0.2:
STU
3).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
Continuous
Integration
Build
of
available
versions,
see
FHIR
(will
be
incorrect/inconsistent
at
times).
See
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
R3
R2
|
Responsible
Owner:
|
|
Raw JSON ( canonical form + also see JSON Format Specification )
Definition for Value SetAll Security Labels
{
"resourceType": "ValueSet",
"id": "security-labels",
"meta": {
"lastUpdated": "2019-10-24T11:53:00+11:00",
"profile": [
"http://hl7.org/fhir/StructureDefinition/shareablevalueset"
]
"resourceType" : "ValueSet",
"id" : "security-labels",
"meta" : {
"lastUpdated" : "2025-11-17T19:23:40.261+00:00"
},
"text": {
"status": "generated",
"div": "<div>!-- Snipped for Brevity --></div>"
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet security-labels</b></p><a name=\"security-labels\"> </a><a name=\"hcsecurity-labels\"> </a><p>This value set includes codes based on the following rules:</p><ul><li>Import all the codes that are contained in <a href=\"http://terminology.hl7.org/7.0.0/ValueSet-v3-Confidentiality.html\">Confidentiality</a></li><li>Import all the codes that are contained in <a href=\"http://terminology.hl7.org/7.0.0/ValueSet-v3-InformationSensitivityPolicy.html\">InformationSensitivityPolicy</a></li><li>Import all the codes that are contained in <a href=\"http://terminology.hl7.org/7.0.0/ValueSet-v3-Compartment.html\">Compartment</a></li><li>Import all the codes that are contained in <a href=\"http://terminology.hl7.org/7.0.0/ValueSet-v3-SecurityIntegrityObservationValue.html\">SecurityIntegrityObservationValue</a></li><li>Import all the codes that are contained in <a href=\"http://terminology.hl7.org/7.0.0/ValueSet-v3-SecurityControlObservationValue.html\">SecurityControlObservationValue</a></li><li>Import all the codes that are contained in <a href=\"http://terminology.hl7.org/7.0.0/ValueSet-v3-ActUSPrivacyLaw.html\">ActUSPrivacyLaw</a></li></ul></div>"
},
"extension": [
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode" : "fhir"
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode" : "normative"
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger" : 6
}],
"url" : "http://hl7.org/fhir/ValueSet/security-labels",
"identifier" : [{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.3.47"
},
{
"use" : "old",
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.3.46"
},
{
"use" : "old",
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.4.642.2.31"
}],
"version" : "6.0.0-ballot3",
"name" : "AllSecurityLabels",
"title" : "All Security Labels",
"status" : "active",
"experimental" : false,
"date" : "2025-11-01",
"publisher" : "HL7 International / FHIR Infrastructure",
"contact" : [{
"telecom" : [{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/secure"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status",
"valueString": "Informative"
"system" : "email",
"value" : "fhir@lists.hl7.org"
}]
},
{
"telecom" : [{
"system" : "url",
"value" : "http://www.hl7.org/Special/committees/fiwg"
}]
}],
"description" : "A single value set for all security labels defined by FHIR.",
"jurisdiction" : [{
"coding" : [{
"system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code" : "001",
"display" : "World"
}]
}],
"compose" : {
"include" : [{
"valueSet" : ["http://terminology.hl7.org/ValueSet/v3-Confidentiality"]
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 3
"valueSet" : ["http://terminology.hl7.org/ValueSet/v3-InformationSensitivityPolicy"]
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "sec"
}
],
"url": "http://hl7.org/fhir/ValueSet/security-labels",
"identifier": [
"valueSet" : ["http://terminology.hl7.org/ValueSet/v3-Compartment"]
},
{
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:2.16.840.1.113883.4.642.3.46"
}
],
"version": "3.0.2",
"name": "All Security Labels",
"status": "draft",
"experimental": true,
"date": "2014-07-28",
"publisher": "FHIR project team",
"contact": [
"valueSet" : ["http://terminology.hl7.org/ValueSet/v3-SecurityIntegrityObservationValue"]
},
{
"telecom": [
{
"system": "url",
"value": "http://hl7.org/fhir"
}
]
}
],
"description": "A single value set for all security labels defined by FHIR.",
"compose": {
"include": [
{
"valueSet": [
"http://hl7.org/fhir/ValueSet/v3-ConfidentialityClassification"
]
},
{
"valueSet": [
"http://hl7.org/fhir/ValueSet/v3-InformationSensitivityPolicy"
]
},
{
"valueSet": [
"http://hl7.org/fhir/ValueSet/v3-Compartment"
]
},
{
"valueSet": [
"http://hl7.org/fhir/ValueSet/v3-SecurityIntegrityObservationValue"
]
},
{
"valueSet": [
"http://hl7.org/fhir/ValueSet/v3-SecurityControlObservationValue"
]
},
{
"valueSet": [
"http://hl7.org/fhir/ValueSet/v3-ActUSPrivacyLaw"
]
}
]
"valueSet" : ["http://terminology.hl7.org/ValueSet/v3-SecurityControlObservationValue"]
},
{
"valueSet" : ["http://terminology.hl7.org/ValueSet/v3-ActUSPrivacyLaw"]
}]
}
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
Release
3
(STU;
v3.0.2-11200)
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Thurs,
Oct
24,
2019
11:53+1100.
QA
Page
Mon,
Nov
17,
2025
19:27+0000.
Links:
Search
|
Version
History
|
Table
of
Contents
|
Credits
Glossary
|
QA
|
Compare
to
DSTU2
R4
|
Compare
to
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change