FHIR Release 3 (STU) CI-Build

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0 . For a full list Continuous Integration Build of available versions, see FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Valueset-procedure-followup.json

Example ValueSet/procedure-followup (JSON)

Maturity Level : N/A
Responsible Owner: Vocabulary Terminology Infrastructure Work Group Ballot Standards Status : Informative

Raw JSON ( canonical form + also see JSON Format Specification )

Definition for Value SetProcedure Follow up Codes (SNOMED CT)

{
  "resourceType": "ValueSet",
  "id": "procedure-followup",
  "meta": {
    "lastUpdated": "2019-10-24T11:53:00+11:00",
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/shareablevalueset"
    ]

  "resourceType" : "ValueSet",
  "id" : "procedure-followup",
  "meta" : {
    "lastUpdated" : "2025-11-08T11:23:29.301+00:00"

  },
  "text": {
    "status": "generated",
    "div": "<div>!-- Snipped for Brevity --></div>"

  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ValueSet procedure-followup</b></p><a name=\"procedure-followup\"> </a><a name=\"hcprocedure-followup\"> </a><ul><li>Include these codes as defined in <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a><span title=\"Version is not explicity stated. No matching Code System found\"> version Not Stated (use latest from terminology server)</span><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"http://snomed.info/id/18949003\">18949003</a></td><td style=\"color: #cccccc\">Change of dressing</td></tr><tr><td><a href=\"http://snomed.info/id/30549001\">30549001</a></td><td style=\"color: #cccccc\">Removal of suture</td></tr><tr><td><a href=\"http://snomed.info/id/241031001\">241031001</a></td><td style=\"color: #cccccc\">Removal of drain</td></tr><tr><td><a href=\"http://snomed.info/id/35963001\">35963001</a></td><td style=\"color: #cccccc\">Removal of staples</td></tr><tr><td><a href=\"http://snomed.info/id/225164002\">225164002</a></td><td style=\"color: #cccccc\">Removal of ligature</td></tr><tr><td><a href=\"http://snomed.info/id/447346005\">447346005</a></td><td style=\"color: #cccccc\">Cardiopulmonary exercise test (procedure)</td></tr><tr><td><a href=\"http://snomed.info/id/229506003\">229506003</a></td><td style=\"color: #cccccc\">Scar tissue massage</td></tr><tr><td><a href=\"http://snomed.info/id/274441001\">274441001</a></td><td style=\"color: #cccccc\">Suction drainage</td></tr><tr><td><a href=\"http://snomed.info/id/394725008\">394725008</a></td><td style=\"color: #cccccc\">Diabetes medication review (procedure)</td></tr><tr><td><a href=\"http://snomed.info/id/359825008\">359825008</a></td><td style=\"color: #cccccc\">Cytopathology, review of bronchioalveolar lavage specimen</td></tr></table></li></ul></div>"

  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status",
      "valueString": "Informative"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 1
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "pc"
    }
  ],
  "url": "http://hl7.org/fhir/ValueSet/procedure-followup",
  "identifier": [
    {
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:2.16.840.1.113883.4.642.3.420"
    }
  ],
  "version": "3.0.2",
  "name": "Procedure Follow up Codes (SNOMED CT)",
  "status": "draft",
  "experimental": true,
  "date": "2019-10-24T11:53:00+11:00",
  "publisher": "FHIR Project team",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://hl7.org/fhir"
        }
      ]
    }
  ],
  "description": "Procedure follow up codes: a selection of SNOMED CT codes relevant to procedure follow up.",
  "copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.",
  "compose": {
    "include": [

  "extension" : [{
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
    "valueCode" : "pc"
  },
  {
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
    "valueCode" : "draft"
  },
  {
    "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
    "valueInteger" : 1
  }],
  "url" : "http://hl7.org/fhir/ValueSet/procedure-followup",
  "identifier" : [{
    "system" : "urn:ietf:rfc:3986",
    "value" : "urn:oid:2.16.840.1.113883.4.642.3.429"
  },
  {
    "use" : "old",
    "system" : "urn:ietf:rfc:3986",
    "value" : "urn:oid:2.16.840.1.113883.4.642.3.420"
  },
  {
    "use" : "old",
    "system" : "urn:ietf:rfc:3986",
    "value" : "urn:oid:2.16.840.1.113883.4.642.2.240"
  }],
  "version" : "6.0.0-ballot3",
  "name" : "ProcedureFollowUpCodesSNOMEDCT",
  "title" : "Procedure Follow up Codes (SNOMED CT)",
  "status" : "draft",
  "experimental" : false,
  "publisher" : "FHIR Project team",
  "contact" : [{
    "telecom" : [{
      "system" : "url",
      "value" : "http://hl7.org/fhir"
    }]
  }],
  "description" : "Procedure follow up codes: A selection of SNOMED CT codes relevant to procedure follow up.",
  "jurisdiction" : [{
    "coding" : [{
      "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
      "code" : "001",
      "display" : "World"
    }]
  }],
  "copyright" : "This resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org",
  "compose" : {
    "include" : [{
      "system" : "http://snomed.info/sct",
      "concept" : [{
        "code" : "18949003"
      },

      {
        "system": "http://snomed.info/sct",
        "concept": [
          {
            "code": "18949003"
          },
          {
            "code": "30549001"
          },
          {
            "code": "241031001"
          },
          {
            "code": "35963001"
          },
          {
            "code": "225164002"
          },
          {
            "code": "447346005"
          },
          {
            "code": "229506003"
          },
          {
            "code": "274441001"
          },
          {
            "code": "394725008"
          },
          {
            "code": "359825008"
          }
        ]
      }
    ]

        "code" : "30549001"
      },
      {
        "code" : "241031001"
      },
      {
        "code" : "35963001"
      },
      {
        "code" : "225164002"
      },
      {
        "code" : "447346005"
      },
      {
        "code" : "229506003"
      },
      {
        "code" : "274441001"
      },
      {
        "code" : "394725008"
      },
      {
        "code" : "359825008"
      }]
    }]

  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.