Publish-box
(todo)
This
is
the
Continuous
Integration
Build
of
FHIR
(will
be
incorrect/inconsistent
at
times).
See
the
Directory
of
published
versions
| Responsible Owner: Terminology Infrastructure Work Group | Standards Status : Informative |
Raw XML ( canonical form + also see XML Format Specification )
Definition for Value SetVital Signs - Heart Rate
<?xml version="1.0" encoding="UTF-8"?> <ValueSet xmlns="http://hl7.org/fhir"> <id value="observation-vitalsign-heartrate"/> <meta><lastUpdated value="2025-11-20T23:56:49.898+00:00"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p class="res-header-id"> <b> Generated Narrative: ValueSet observation-vitalsign-heartrate</b> </p> <a name="observation-vitalsign-heartrate"> </a> <a name="hcobservation-vitalsign-heartrate"> </a>display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60% Profile:<p> This value set includes codes based on the following rules:</p> <ul> <li> Include codes from <a href="http://loinc.org"> <code> http://loinc.org</code>where COMPONENT in LP72677-5,LP308218-9,LP308219-7,LP308220-5,LP308221-3, PROPERTY</a> <span title="Version is not explicity stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span> where COMPONENT in LP72677-5,LP308218-9,LP308219-7,LP308220-5,LP308221-3, PROPERTY = LP6839-7 (NRat), TIME_ASPCT = LP6960-1 (Pt) and SCALE_TYP = LP7753-9 (Qn) </li> </ul> <p> This value set excludes codes based on the following rules:</p> <ul> <li> Exclude codes from <a href="http://loinc.org"> <code> http://loinc.org</code>where SYSTEM = LP310004-9 (^Fetus)</a> <span title="Version is not explicity stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span> where SYSTEM = LP310004-9 (^Fetus) </li> </ul> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="oo"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"> <valueCode value="normative"/> </extension> <url value="http://hl7.org/fhir/ValueSet/observation-vitalsign-heartrate"/> <version value="6.0.0-ballot3"/> <name value="VitalSignsHeartRate"/> <title value="Vital Signs - Heart Rate"/> <status value="active"/> <experimental value="false"/> <publisher value="FHIR project team"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org/fhir"/> </telecom> </contact> <description value="This value set defines the set of LOINC codes considered to be appropriate for representing heart rate vital sign measurements in Observation.code."/> <jurisdiction> <coding> <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/> <code value="001"/> <display value="World"/> </coding> </jurisdiction> <copyright value="This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use"/> <compose> <include> <system value="http://loinc.org"/> <filter> <property value="COMPONENT"/> <op value="in"/> <value value="LP72677-5,LP308218-9,LP308219-7,LP308220-5,LP308221-3"/> </filter> <filter> <property value="PROPERTY"/> <op value="="/> <value value="LP6839-7"/> </filter> <filter> <property value="TIME_ASPCT"/> <op value="="/> <value value="LP6960-1"/> </filter> <filter> <property value="SCALE_TYP"/> <op value="="/> <value value="LP7753-9"/> </filter> </include> <exclude> <system value="http://loinc.org"/> <filter> <property value="SYSTEM"/> <op value="="/> <value value="LP310004-9"/> </filter> </exclude> </compose> </ ValueSet >
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR
®©
HL7.org
2011+.
FHIR
R6
hl7.fhir.core#6.0.0-ballot3
generated
on
Tue,
Apr
1,
Thu,
Nov
20,
2025
12:22+1100.
23:59+0000.
Links:
Search
|
Version
History
|
Contents
|
Glossary
|
QA
|
Compare
to
R4
|
Compare
to
R5
|
Compare
to
Last
Ballot
|
|
Propose
a
change