Release 5 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v5.0.0: R5 - STU ). This is the current published version in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). For a full list of available versions, see times).
See the Directory of published versions icon

4.4.1.351 4.4.1.656 ValueSet http://hl7.org/fhir/ValueSet/imagingselection-status

  Maturity Level : 4
Responsible Owner: Imaging Integration icon Work Group Trial Use Normative Use Context : Country: World, Not yet ready for Production use World
Official URL : http://hl7.org/fhir/ValueSet/imagingselection-status Version : 5.0.0 6.0.0-ballot3
draft active as of 2022-06-29 2024-06-13 Computable Name : ImagingSelectionStatus
Flags : Experimental, Immutable OID : 2.16.840.1.113883.4.642.3.3096

This value set is used in the following places:

The status of the ImagingSelection.


Generated Narrative: ValueSet imagingselection-status

Last updated: 2025-11-20T23:56:49.898Z

 

This expansion generated 26 Mar 2023 20 Nov 2025


This value set contains 3 concepts

ValueSet

Expansion performed internally based on codesystem Imaging Selection Status v5.0.0 v6.0.0-ballot3 (CodeSystem)

This value set contains 4 concepts

http://hl7.org/fhir/imagingselection-status http://hl7.org/fhir/imagingselection-status
Code System System Code Display Definition Canonical Mapping for "Imaging Selection Status"
http://hl7.org/fhir/imagingselection-status    available Available The selected resources are available.. ~ active
http://hl7.org/fhir/imagingselection-status    entered-in-error Entered in Error The imaging selection has been withdrawn following a release. This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "cancelled" "inactive" rather than "entered-in-error".). ~ error
http://hl7.org/fhir/imagingselection-status    unknown inactive Inactive The imaging selection is no longer valid. ~ inactive
http://hl7.org/fhir/imagingselection-status    unknown Unknown The system does not know which of the status values currently applies for this request. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, it's just not known which one. ~ unknown

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

Lvl A few code lists that FHIR defines are hierarchical - each code is assigned a level. For value sets, levels are mostly used to organize codes for user convenience, but may follow code system hierarchy - see Code System for further information
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding ). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code