This
page
is
part
of
the
Continuous
Integration
Build
of
FHIR
Specification
(v4.0.1:
R4
-
Mixed
Normative
and
STU
)
in
it's
permanent
home
(it
will
always
(will
be
available
incorrect/inconsistent
at
this
URL).
The
current
version
which
supercedes
this
version
is
5.0.0
.
For
a
full
list
of
available
versions,
see
times).
See
the
Directory
of
published
versions
.
Page
versions:
R5
R4B
R4
| Responsible Owner: Orders and Observations Work Group | Standards Status : Informative |
Compartments
:
|
This is the narrative for the resource. See also the XML , JSON or Turtle format. This example conforms to the profile SpecimenDefinition .
Generated
Narrative
with
Details
Narrative:
SpecimenDefinition
2364
id
StructureDefinition
Work
Group
:
2364
oo
url : SpecimenDefinition Example Specimen Definition for Testing
identifier : 12345
title : Example Specimen Definition for Testing
status : Active
experimental : false
publisher : HL7 International / Orders and Observations
contact : http://www.hl7.org/Special/committees/orders
typeCollected
:
Venous
blood
specimen
(Details
:
{SNOMED
CT
code
'122555007'
=
'Venous
blood
specimen',
given
as
'Venous
blood
specimen'})
patientPreparation
:
12
hour
fasting
(Details
)
,
At
rest
(Details
:
{SNOMED
CT
code
'263678003'
=
'At
rest',
given
as
'At
rest'})
timeAspect : preferrably morning time
typeTested
isDerived : false
type : Serum specimen
(Details : {SNOMED CT code '119364003' = 'Serum specimen', given as 'Serum specimen'})preference :
preferredPreferredContainers
Material Type Cap MinimumVolume[x] plastic (Details : {SNOMED CT code '61088005' = 'Plastic', given as 'plastic'})Evacuated blood collection tube, thrombin/clot activator/gel separator (Details : {SNOMED CT code '702281005' = 'Evacuated blood collection tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube, thrombin/clot activator/gel separator'})yellow cap (Details : {urn:iso:std:iso:6710:2017 code 'yellow' = 'yellow', given as 'yellow cap'})2 ml (Details: UCUM code mLcodemL = 'mL')handling
temperatureQualifier : Ambient temperature
(Details )temperatureRange : 15-25 °C
MaxDurations
maxDuration :ValueUnit System Code 60 minute (Details: UCUM codehttp://unitsofmeasure.org min = 'min')handling
temperatureQualifier : Refrigerated temperature
(Details )temperatureRange : 2-8 °C
MaxDurations
maxDuration :ValueUnit System Code 8 hour (Details: UCUM codehttp://unitsofmeasure.org h = 'h')
typeTested
type : Plasma specimen
(Details : {SNOMED CT code '119361006' = 'Plasma specimen', given as 'Plasma specimen'})preference :
alternateAlternateContainers
Material Type Cap MinimumVolume[x] glass (Details : {SNOMED CT code '32039001' = 'Glass', given as 'glass'})Evacuated blood collection tube with heparin lithium and geltube, thrombin/clot activator/gel separator(Details : {SNOMED CT code '767390000' = 'Evacuated blood collection tube with heparin lithium and gel separator', given as 'Evacuated blood collection tube with heparin lithium and gel separator'})green cap (Details : {urn:iso:std:iso:6710:2017 code 'green' = 'green', given as 'green cap'})2 ml (Details: UCUM code mLcodemL = 'mL')rejectionCriterion : insufficient specimen volume
(Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'insufficient' = 'insufficient specimen volume', given as 'insufficient specimen volume'}), hemolized specimen(Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'hemolized' = 'hemolized specimen', given as 'hemolized specimen'})handling
temperatureQualifier : Ambient temperature
(Details )temperatureRange : 15-25 °C
MaxDurations
maxDuration :ValueUnit System Code 60 minute (Details: UCUM codehttp://unitsofmeasure.org min = 'min')handling
temperatureQualifier : Refrigerated temperature
(Details )temperatureRange : 2-8 °C
MaxDurations
maxDuration :ValueUnit System Code 8 hour (Details: UCUM codehttp://unitsofmeasure.org h = 'h')
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.