Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4

Servicerequest-example-lipid.json

Example ServiceRequest/lipid (JSON)

Maturity Level : N/A
Responsible Owner: Orders and Observations Work Group Standards Status : Informative Compartments : Device , Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Lipid Panel Order

{
  "resourceType": "ServiceRequest",
  "id": "lipid",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: lipid</p><p><b>contained</b>: , </p><p><b>identifier</b>: Placer = 2345234234234</p><p><b>status</b>: active</p><p><b>intent</b>: original-order</p><p><b>code</b>: Lipid Panel <span>(Details : {http://acme.org/tests code 'LIPID' = 'LIPID)</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>encounter</b>: <a>Encounter/example</a></p><p><b>occurrence</b>: 02/05/2013 4:16:00 PM</p><p><b>requester</b>: <a>Practitioner/example</a></p><p><b>performer</b>: <a>Practitioner/f202</a></p><p><b>reasonCode</b>: Fam hx-ischem heart dis <span>(Details : {ICD-9 code 'V173' = 'V173', given as 'Fam hx-ischem heart dis'})</span></p><p><b>supportingInfo</b>: Fasting status. Generated Summary: id: fasting; status: final; Fasting status - Reported <span>(Details : {LOINC code '49541-6' = 'Fasting status - Reported', given as 'Fasting status - Reported'})</span>; Yes <span>(Details : {http://terminology.hl7.org/CodeSystem/v2-0136 code 'Y' = 'Yes', given as 'Yes'})</span></p><p><b>specimen</b>: Serum specimen. Generated Summary: id: serum; 20150107-0012; Serum sample <span>(Details : {SNOMED CT code '119364003' = 'Serum specimen', given as 'Serum sample'})</span></p><p><b>note</b>: patient is afraid of needles</p></div>"

  "resourceType" : "ServiceRequest",
  "id" : "lipid",
  "contained" : [{
    "resourceType" : "Observation",
    "id" : "fasting",
    "status" : "final",
    "code" : {
      "coding" : [{
        "system" : "http://loinc.org",
        "code" : "49541-6",
        "display" : "Fasting status - Reported"
      }]
    },
    "subject" : {
      "reference" : "Patient/example"
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
        "code" : "Y",
        "display" : "Yes"
      }]
    }

  },
  "contained": [
    {
      "resourceType": "Observation",
      "id": "fasting",
      "status": "final",
      "code": {
        "coding": [
          {
            "system": "http://loinc.org",
            "code": "49541-6",
            "display": "Fasting status - Reported"
          }
        ]
      },
      "subject": {
        "reference": "Patient/example"
      },
      "valueCodeableConcept": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0136",
            "code": "Y",
            "display": "Yes"
          }
        ]
      }

  {
    "resourceType" : "Specimen",
    "id" : "serum",
    "identifier" : [{
      "system" : "http://acme.org/specimens",
      "value" : "20150107-0012"
    }],
    "type" : {
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "119364003",
        "display" : "Serum sample"
      }]

    },
    {
      "resourceType": "Specimen",
      "id": "serum",
      "identifier": [
        {
          "system": "http://acme.org/specimens",
          "value": "20150107-0012"
        }
      ],
      "type": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "119364003",
            "display": "Serum sample"
          }
        ]
      },
      "subject": {
        "reference": "Patient/example"
      },
      "collection": {
        "collectedDateTime": "2015-08-16T06:40:17Z"
      }

    "subject" : {
      "reference" : "Patient/example"
    },
    "collection" : {
      "collectedDateTime" : "2015-08-16T06:40:17Z"

    }
  ],
  "identifier": [
    {
      "type": {
        "coding": [
          {
            "system": "http://terminology.hl7.org/CodeSystem/v2-0203",
            "code": "PLAC"
          }
        ],
        "text": "Placer"
      },
      "system": "urn:oid:1.3.4.5.6.7",
      "value": "2345234234234"

  }],
  "identifier" : [{
    "type" : {
      "coding" : [{
        "system" : "http://terminology.hl7.org/CodeSystem/v2-0203",
        "code" : "PLAC"
      }],
      "text" : "Placer"
    },
    "system" : "urn:oid:1.3.4.5.6.7",
    "value" : "2345234234234"
  }],
  "status" : "active",
  "intent" : "original-order",
  "code" : {
    "concept" : {
      "coding" : [{
        "system" : "http://acme.org/tests",
        "code" : "LIPID"
      }],
      "text" : "Lipid Panel"

    }
  ],
  "status": "active",
  "intent": "original-order",
  "code": {
    "coding": [
      {
        "system": "http://acme.org/tests",
        "code": "LIPID"
      }
    ],
    "text": "Lipid Panel"

  },
  "subject": {
    "reference": "Patient/example"

  "subject" : {
    "reference" : "Patient/example"

  },
  "encounter": {
    "reference": "Encounter/example"

  "encounter" : {
    "reference" : "Encounter/example"

  },
  "occurrenceDateTime": "2013-05-02T16:16:00-07:00",
  "requester": {
    "reference": "Practitioner/example"

  "occurrenceDateTime" : "2013-05-02T16:16:00-07:00",
  "requester" : {
    "reference" : "Practitioner/example"

  },
  "performer": [
    {
      "reference": "Practitioner/f202"
    }
  ],
  "reasonCode": [
    {
      "coding": [
        {
          "system": "http://hl7.org/fhir/sid/icd-9",
          "code": "V173",
          "display": "Fam hx-ischem heart dis"
        }
      ]
    }
  ],
  "supportingInfo": [
    {
      "reference": "#fasting",
      "display": "Fasting status"
    }
  ],
  "specimen": [
    {
      "reference": "#serum",
      "display": "Serum specimen"

  "performer" : [{
    "reference" : "Practitioner/f202"
  }],
  "reason" : [{
    "concept" : {
      "coding" : [{
        "system" : "http://hl7.org/fhir/sid/icd-9",
        "code" : "V173",
        "display" : "Fam hx-ischem heart dis"
      }]

    }
  ],
  "note": [
    {
      "text": "patient is afraid of needles"

  }],
  "supportingInfo" : [{
    "reference" : {
      "reference" : "#fasting",
      "display" : "Fasting status"

    }
  ]

  }],
  "specimen" : [{
    "reference" : "#serum",
    "display" : "Serum specimen"
  }],
  "note" : [{
    "text" : "patient is afraid of needles"
  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.