FHIR Release 3 (STU) CI-Build

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0 . For a full list Continuous Integration Build of available versions, see FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Procedure-example-implant.xml

Example Procedure/example-implant (XML)

Maturity Level : N/A
Responsible Owner: Patient Care Work Group Ballot Standards Status : Informative Compartments : Encounter , Group , Patient , Practitioner , RelatedPerson

Raw XML ( canonical form ) Jump past Narrative + also see XML Format Specification )

Example of a device manipulation (id = "example-implant")

(Details : {SNOMED CT code '25267002' = 'Insertion of intracardiac pacemaker', given as 'Insertion of intracardiac pacemaker (procedure)'})
<?xml version="1.0" encoding="UTF-8"?>

<Procedure xmlns="http://hl7.org/fhir">  <id value="example-implant"/>   <!--   <association> 
      <status> 
        <coding>
          <system value="http://hl7.org/fhir/device-association-status"/>
          <code value="implanted"/>
        </coding>
      </status>
      <humanSubject> 
        <reference value="Patient/example"/> 
      </humanSubject> 
    </association>    -->
  <contained>     <Device>       <id value="example-pacemaker"/>       <manufacturer value="Acme Devices, Inc"/>       <lotNumber value="1234-5678"/>       <type>         <coding>           <system value="http://snomed.info/sct"/>           <code value="14106009"/>           <display value="Cardiac pacemaker, device (physical object)"/>         </coding>       </type>     </Device>   </contained>   <status value="completed"/>   <code>     <coding>       <system value="http://snomed.info/sct"/>       <code value="25267002"/>       <display value="Insertion of intracardiac pacemaker (procedure)"/>     </coding>     <text value="Implant Pacemaker"/>   </code>   <subject>     <reference value="Patient/example"/>   </subject>   <occurrenceDateTime value="2015-04-05"/>   <performer>     <actor>       <reference value="Practitioner/example"/>       <display value="Dr Cecil Surgeon"/>     </actor>   </performer>   <reason>     <concept>       <text value="Bradycardia"/>     </concept>   </reason>   <followUp>     <concept>       <text value="ROS 5 days  - 2013-04-10"/>     </concept>   </followUp>   <note>     <text value="Routine Appendectomy. Appendix was inflamed and in retro-caecal position"/>   </note>   <focalDevice>     <action>       <coding>         <system value="http://hl7.org/fhir/device-action"/>         <code value="implanted"/>       </coding>     </action>     <manipulated>       <reference value="#example-pacemaker"/>     </manipulated>   </focalDevice> 


</

Procedure

>



Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.