Release 4 FHIR CI-Build

This page is part of the Continuous Integration Build of FHIR Specification (v4.0.1: R4 - Mixed Normative and STU ) in it's permanent home (it will always (will be available incorrect/inconsistent at this URL). The current version which supercedes this version is 5.0.0 . For a full list of available versions, see times).
See the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Procedure-example-implant.json

Example Procedure/example-implant (JSON)

Maturity Level : N/A
Responsible Owner: Patient Care Work Group Standards Status : Informative Compartments : Encounter , Group , Patient , Practitioner , RelatedPerson

Raw JSON ( canonical form + also see JSON Format Specification )

Example of a device manipulation

{
  "resourceType": "Procedure",
  "id": "example-implant",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-implant</p><p><b>status</b>: completed</p><p><b>code</b>: Implant Pacemaker <span>(Details : {SNOMED CT code '25267002' = 'Insertion of intracardiac pacemaker', given as 'Insertion of intracardiac pacemaker (procedure)'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>performed</b>: 05/04/2015</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Dr Cecil Surgeon</a></td></tr></table><p><b>reasonCode</b>: Bradycardia <span>(Details )</span></p><p><b>followUp</b>: ROS 5 days  - 2013-04-10 <span>(Details )</span></p><p><b>note</b>: Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p><h3>FocalDevices</h3><table><tr><td>-</td><td><b>Action</b></td><td><b>Manipulated</b></td></tr><tr><td>*</td><td>Implanted <span>(Details : {http://hl7.org/fhir/device-action code 'implanted' = 'Implanted)</span></td><td><a>Device/example-pacemaker</a></td></tr></table></div>"
  },
  "status": "completed",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "25267002",
        "display": "Insertion of intracardiac pacemaker (procedure)"
      }
    ],
    "text": "Implant Pacemaker"

  "resourceType" : "Procedure",
  "id" : "example-implant",
  "contained" : [{
    "resourceType" : "Device",
    "id" : "example-pacemaker",
    "manufacturer" : "Acme Devices, Inc",
    "lotNumber" : "1234-5678",
    "type" : [{
      "coding" : [{
        "system" : "http://snomed.info/sct",
        "code" : "14106009",
        "display" : "Cardiac pacemaker, device (physical object)"
      }]
    }]
  }],
  "status" : "completed",
  "code" : {
    "coding" : [{
      "system" : "http://snomed.info/sct",
      "code" : "25267002",
      "display" : "Insertion of intracardiac pacemaker (procedure)"
    }],
    "text" : "Implant Pacemaker"

  },
  "subject": {
    "reference": "Patient/example"

  "subject" : {
    "reference" : "Patient/example"

  },
  "performedDateTime": "2015-04-05",
  "performer": [
    {
      "actor": {
        "reference": "Practitioner/example",
        "display": "Dr Cecil Surgeon"
      }
    }
  ],
  "reasonCode": [
    {
      "text": "Bradycardia"

  "occurrenceDateTime" : "2015-04-05",
  "performer" : [{
    "actor" : {
      "reference" : "Practitioner/example",
      "display" : "Dr Cecil Surgeon"

    }
  ],
  "followUp": [
    {
      "text": "ROS 5 days  - 2013-04-10"

  }],
  "reason" : [{
    "concept" : {
      "text" : "Bradycardia"

    }
  ],
  "note": [
    {
      "text": "Routine Appendectomy. Appendix was inflamed and in retro-caecal position"

  }],
  "followUp" : [{
    "concept" : {
      "text" : "ROS 5 days  - 2013-04-10"

    }
  ],
  "focalDevice": [
    {
      "action": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/device-action",
            "code": "implanted"
          }
        ]
      },
      "manipulated": {
        "reference": "Device/example-pacemaker"
      }

  }],
  "note" : [{
    "text" : "Routine Appendectomy. Appendix was inflamed and in retro-caecal position"
  }],
  "focalDevice" : [{
    "action" : {
      "coding" : [{
        "system" : "http://hl7.org/fhir/device-action",
        "code" : "implanted"
      }]
    },
    "manipulated" : {
      "reference" : "#example-pacemaker"

    }
  ]

  }]

}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.